RESISTANCE HiTESTER
RM3542
Measure in as Fast as 0.9 ms, Optimized for Automated Systems
Hioki DC resistance meters measure a broad range of resistance values at a high level of precision. The RM3542 deliver high speed, high precision, and high reliability, indispensable for the shipping inspection of devices such as resistors and EMI components. The resistance meter also supports chip resistor sampling inspections, helping resistor manufacturers improve productivity. Key Features • High speed and accuracy maximize productivity in automated systems • Multiple checking functions ensure proper contact for reliable measurements • Low-power resistance mode measures chip inductors and EMC suppression components • Supports sample inspections during the manufacturing process
RM3542 | |
---|---|
RM3542-01 | Built in GP-IB interface |
Test fixtures are not supplied with the unit. Please select an optional test fixture when ordering.
The RM3542 improves contact with measurement specimens by eliminating oxide films and dirt between the probes and specimens. By addressing faulty contact, the instrument facilitates stable measurement and reduces the contact error rate, boosting productivity.
Resistance range | [at Low Power OFF] 100 mΩ range (Max. 120.0000 mΩ, 0.1 μΩ resolution) to 100 MΩ range (Max. 120.0000 MΩ, 100 Ω resolution), 10 steps [at Low Power ON] 1000 mΩ range (Max. 1200.000 mΩ, 1 μΩ resolution) to 1000 Ω range (Max. 1200.000 Ω, 1 mΩ resolution), 4 steps |
---|---|
Display | Monochrome graphic LCD 240 × 64 dot, white LED backlight |
Measurement accuracy | [with SLOW mode, at 100 mΩ range] ±0.015 % rdg. ±0.002 % f.s. [with SLOW mode, at 1000 Ω range] ±0.006 % rdg. ±0.001 % f.s. (the best case) |
Testing current | [at 100 mΩ range] 100 mA DC to [at 100 MΩ range] 100 nA DC |
Open-terminal voltage | 20 V DC max. |
Sampling rate | FAST, MEDIUM, SLOW, 3 settings |
Measurement times | [at 100 Ω /1000 Ω ranges, with Low Power OFF] FAST: 0.9 ms, MED: 3.6 ms, SLOW: 17 ms (minimum time) |
Integration time | 0.1 ms to 100.0 ms, or 1 to 5 PLC at 50 Hz, 1 to 6 PLC at 60 Hz Note: PLC = one power line cycle (mains wave-form period) |
Other functions | Comparator (compare setting value with measurement value), Delay (set to allow for mechanical delay of trigger input and probing, or set to allow for measurement object response), OVC (offset voltage compensation), Measurement fault detection, Probe short-circuit detection, Improve contact, Auto-memory, Statistical calculations, Settings monitor (when using two instruments, a difference in settings causes warning notification), Retry, Trigger function. etc,. |
Interfaces | RS-232C, Printer, GP-IB (Model RM3542-01) |
External I/O | Trigger, Hold input, Comparator output, Settings monitor terminal |
Power supply | 100 to 240 V AC, 50/60 Hz, 30 VA max. |
Dimensions and mass | 260 mm (10.24 in) W × 88 mm (3.46 in) H × 300 mm (11.81 in) D, 2.9 kg (102.3 oz) |
Accessories | Power cord ×1, EXT. I/O male connector ×1, Instruction manual ×1, Operation guide ×1 |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Catalog: RESISTANCE METER RM3542A, RM3542 | Download PDF [2MB] |
English |
Technical Note: Shunt Resistor Measurement Vol.5 | Download PDF [513KB] |
English |
Technical Note: Wide or Thick Resistor Measurement Vol.4 | Download PDF [4MB] |
English |
Technical Note: Introduction to Resistance Measurement Vol.1 | Download PDF [1MB] |
English |
Resistance Measurement Handbook | Download PDF [1MB] |
English |
If you can not download, log into your myHioki account to access more technical documents and information where available.
RESISTANCE HiTESTER RM3542,RM3542-01 [209KB] |
Operation Guide |
English |
Ver.00 |
RESISTANCE HiTESTER RM3542,RM3542-01 [583KB] |
Operation Guide |
Simplified Chinese |
Ver.00 |
RESISTANCE HiTESTER RM3542,RM3542-01 [5MB] |
Instruction Manual |
English |
Ver.06 |
RESISTANCE HiTESTER RM3542,RM3542-01 [5MB] |
Instruction Manual |
Simplified Chinese |
Ver.04 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
RESISTANCE HiTESTER RM3542 [77KB] |
Ver.03 |
RESISTANCE HiTESTER RM3542-01 [78KB] |
Ver.03 |
No results were found. |
RESISTANCE HiTESTER RM3542,RM3542-01 [121KB] |
Ver.08 |
LabVIEW driver for RESISTANCE HiTESTER RM3542 RM3542A RM3543 RM3543-01 | Freeware | Version 1.00 |
RESISTANCE HiTESTER RM3542・RM3542A・RM3543 Data Capture Software | Freeware | Version 1.01 |
Sample program for communication with HIOKI products | Freeware | V2.10 |
No results were found. |
4-TERMINAL PROBE 9140
DC to 100 kHz, 1 m (3.28 ft) length, impedance characteristics of 75 Ω
TEST FIXTURE 9262
Direct connection type, DC to 8 MHz, measurable conductor diameter: ø0.3 (0.01 in) to 2 mm (0.08 in)
SMD TEST FIXTURE 9263
Direct connection type, DC to 8 MHz, Test sample dimensions:1 mm (0.04 in) to 10 mm (0.39 in)
GP-IB CONNECTOR CABLE 9151-02
2 m (6.56 ft) length
RS-232C CABLE 9637
9 pin - 9 pin, cross, 1.8 m (5.91 ft) length
No results were found.