MEMORY HiCORDER
MR8875
1000V Direct Input, Portable 16-channel Memory Recorder for Data Acquisition During Vehicle Testing with Direct CAN Bus Input
Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple physical phenomena such as voltage, current, temperature, vibration, weight, acceleration and rotation due to complete isolation between channels and from each channel to the ground. The MR8875 data acquisition (DAQ) recorder accommodates plug-and-play input modules to meet applications such as onboard vehicle analysis, current consumption testing of portable devices, and measuring the voltage waveforms of superconducting materials and contacts. Key Features • 1000V input and instantaneous DC or RMS waveform measurement with new Analog Unit MR8905 • Multi-channel logger capable of thermocouple temperature measurement up to 60 ch at 10 msec intervals • Measure multiple channels simultaneously despite handheld portable design • Max. 2 μsec high-speed simultaneous logging for all input channels • Save directly to the SD Card in real time for uninterrupted long-term logging • 16-bit high-resolution measurement of voltage, temperature, distortion and CAN signals • FFT calculation, waveform calculation functions for advanced analysis • Intuitive touch screen for optimal operability • Tough against vibrations and extreme temperatures, with strengthened body ideal for in-vehicle testing and road tests • 3 different power supplies
MR8875 | Max. 16 - 60ch, 32MW memory, main unit only |
---|
FREQUENTLY ASKED QUESTIONS Note: Test leads are not included. Purchase the leads appropriate for your application separately. AC Adapter Z1005 is included as standard.
The Hioki MR8875 revolutionizes data logging by letting you record data to the SD Card in real-time in high speeds. Up to 3 full seconds of data logged in as fast as every 2μsec can be precisely captured, and when recording up to 50μsec of data, you can store up to 60 channels of signals, all in real-time into one single SD Card.
Abrupt fluctuations in acceleration can cause unacceptable motion errors in automobiles, transportation equipment and industrial robots. The Hioki MR8857 Memory HiCorder installed with the strain measurement module can greatly assist in helping you measure and analyze these unexpected acceleration fluctuations across 16 channels. Watch this video to learn how to connect distortion gauge acceleration sensors and make proper settings with the intuitive interface, as well as use the recorder’s scaling function to efficiently record waveforms.
Number of input units | Up to 4 slots |
---|---|
Number of channels | Max. 16 analog channels (Max. 60 channels when using the MR8902) + standard 8 logic channels + 2 pulse channels Note: For analog units, channels are isolated from each other and from the MR8875’s GND. For CAN unit ports or standard logic terminals or standard pulse terminals, all channels have common GND. |
Measurement ranges (20 div full-scale) | 5 mV to 10 V/div , 11 ranges (when using the MR8901), 500 mV to 50 V/div , 7 ranges (when using the MR8905), resolution : 1/1250 of range |
Max. rated voltage | Between terminals: 150 V DC Between terminal to earth: 100 V AC, DC (when using the MR8901) |
Frequency characteristics | DC to 100 kHz (-3 dB, when using the MR8901) |
Time axis | 200 µs to 5 min/div, 21 ranges, sampling period: 1/100 of range, External sampling possible |
Max. sampling rate | [When using MR8901] 500 kS/s (2 μs period, all channels simultaneously) [When using MR8902] 10 ms (all input channels are scanned at high speed during every recording interval) [When using MR8903] 200 kS/s (5 μs period, all channels simultaneously) External sampling: 200 kS/s (5 μs period) |
Measurement functions | High-speed function (high speed recording), Real-time calculation between channels, FFT calculation, or other functions |
Storage memory capacity | Total 32 M-words (memory expansion: N/A, 8 MW each input unit) Note: 1 word = 2 bytes, therefore 32 Mega-words = 64 Mega-bytes. Note: Storage memory can be allocated depending on the number of channels used at each input unit |
Removable storage | SD card slot ×1, USB 2.0 memory |
Display | Touch-panel operation 8.4-inch SVGA-TFT color LCD (800 × 600 dots) |
Communication interfaces | LAN: 100BASE-TX (DHCP, DNS supported, FTP server/ client, WEB server, send E-mail, command control) USB: USB 2.0 compliant, series mini-B receptacle ×1 (setting / measure with communication command, or file transfer SD card to PC), series A receptacle ×2 (USB memory, USB mouse/ key-board) |
Power supply | 1) AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 56 VA 2) Battery pack Z1003: 7.2 V DC, 36 VA, continuous operation time: 1 hour with back light ON (AC adapter has priority when used in combination with battery pack), Charges while installed in the MR8875, recharging time: 3 hours 3) External DC Power: 10 to 28 V DC, 56 VA, (please contact your HIOKI distributor for connection cord) |
Dimensions and mass | 298 mm (11.73 in)W × 224 mm (8.82 in)H × 84 mm (3.31 in)D, 2.4 kg (84.7 oz), (excluding input units and the Battery pack Z1003) Reference data: 3.47 kg/ 122.4 oz (including the MR8901 ×4 units and the Battery pack Z1003) |
Accessories | Instruction manual ×1, Measurement guide ×1, AC adapter Z1002 ×1, Protection sheet ×1, USB cable ×1, Shoulder strap ×1, Application disk (Wave viewer Wv, communication commands table, CAN Editor) ×1 |
Compatible models | LabVIEW | MATLAB script |
---|---|---|
MR8875 | Available | Available |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Catalog: MEMORY HiCORDER MR8875 | Download PDF [7MB] |
English |
Catalog: NON-CONTACT AC VOLTAGE PROBE SP3000 | Download PDF [3MB] |
English |
Catalog: HIGH ACCURACY / WIDEBAND CURRENT SENSOR Series CT686x, CT687x, CT684x | Download PDF [6MB] |
English |
Users Guide for MR8875 | Download PDF [3MB] |
English |
If you can not download, log into your myHioki account to access more technical documents and information where available.
MEMORY HiCORDER MR8875 [913KB] |
Measurement Guide |
English |
Ver.02 |
MEMORY HiCORDER MR8875-30 [1MB] |
Measurement Guide |
Simplified Chinese |
Ver.01 |
MEMORY HiCORDER MR8875 [1MB] |
Measurement Guide |
French |
Ver.00 |
MEMORY HiCORDER MR8875 [1MB] |
Measurement Guide |
German |
Ver.00 |
MEMORY HiCORDER MR8875 [9MB] |
Instruction Manual |
English |
Ver.07 |
MEMORY HiCORDER MR8875 [23MB] |
Instruction Manual |
German |
Ver.03 |
MEMORY HiCORDER MR8875 [23MB] |
Instruction Manual |
French |
Ver.03 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
MEMORY HiCORDER MR8875 [147KB] |
Ver.02 |
MEMORY HiCORDER MR8875-30 [146KB] |
Ver.01 |
No results were found. |
MEMORY HiCORDER MR8875 [161KB] |
Ver.07 |
MATLABscript for MEMORY HiCORDERs (8860-50(51) 8861-50(51) MR8827 MR8847(A) MR8875 MR8740 MR8741 MR6000 MR8740T) | Freeware | V2.10 |
MEMORY HiCORDER Model MR8875 LabVIEW 2011 driver | Freeware | Version 1.00 |
MEMORY HiCORDER MR8875 | Firmware | V2.17 |
MEMORY HiCORDER & MEMORY HiLOGGER Application Disk | Freeware | Rev 43 |
No results were found. |
Use only CF Cards or USB drive sold by HIOKI. Compatibility and performance are not guaranteed for CF cards/USB memory stick made by other manufacturers. You may be unable to read from or save data to such cards.
SD MEMORY CARD 2GB Z4001
2 GB capacity
SD MEMORY CARD Z4003
8 GB capacity
USB DRIVE Z4006
16 GB, Long-life, High-reliability SLC Flash Memory
*Install by inserting into the main unit. Can be replaced by user. Input cables are not supplied.
VOLTAGE/TEMP UNIT MR8902
• 15 ch, minute voltage, temperature • Voltage/Thermocouple measurement
STRAIN UNIT MR8903
• 4 ch, acceleration, load, pressure or strain • Strain gauge converter amp
ANALOG UNIT MR8905
・ 2 ch, High-voltage input ・ Max. 1000 VDC, 700 VAC rms ・ DC to 100 kHz bandwidth
*Voltage is limited to the specifications of the input modules in use
GRABBER CLIP 9790-02
Red/black set attaches to the ends of the Connection Cord L9790
CONTACT PIN 9790-03
Red/black set attaches to the ends of the Connection Cord L9790
CONNECTION CORD L9790
• Flexible φ 4.1 mm (0.16 in) thin dia. • Cable allowing for up to 600 V input • 1.8 m (5.91 ft) length
ALLIGATOR CLIP L9790-01
Red/black set attaches to the ends of the Connection Cord L9790
*Voltage is limited to the specifications of the input modules in use
CONNECTION CORD L9198
•φ 5.0 mm (0.20 in) dia. •Cable allows for up to 300 V input •1.7 m (5.58 ft) length •Small alligator clip
* Voltage input via banana terminals limited by the voltage specifications of the respective input unit.
CONNECTION CABLE SET L4940
Banana plug - banana plug, 1.5 m (4.92 ft) length, red/black each 1
EXTENSION CABLE SET L4931
Expands the length of L4930/4940, 1.5 m (4.92 ft) length
ALLIGATOR CLIP SET L4935
Attaches to the tip of the L4930/4940, CAT IV 600 V, CAT III 1000 V
BUS BAR CLIP SET L4936
Attaches to the tip of the L4930/4940, CAT III 600 V
MAGNETIC ADAPTER SET L4937
Attaches to the tip of the L4930/4940, CAT III 1000 V
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length
GRABBER CLIP L9243
Attaches to the tip of the banana plug cable, Red/Black: 1 each, 185 mm (7.28 in.) length
*Voltage to ground is within this product's specifications. Separate power source is also required.
DIFFERENTIAL PROBE P9000
• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply
AC ADAPTER Z1008
100 to 240V AC
*For P9000. Inquire with your Hioki distributor.
(1) Bus powered USB cable
(2) USB(A)- Micro B cable
(3) 3-prong cable
*Voltage to ground is within this product's specifications. Separate power source is also required.
AC ADAPTER 9418-15
100 to 240V AC
NON-CONTACT AC VOLTAGE PROBE SP3000
Sold individually
NON-CONTACT AC VOLTAGE PROBE SP3000
• Supports φ1mm to 2.5mm covered wires • 10Hz to 100kHz frequency bandwidth • 5Vrms 14Vp-p rated measurement voltage
AC VOLTAGE PROBE SP9001
Sold individually
CAN CABLE 9713-01
For the MR8904(MR8875), 8910, Unprocessed on one end, 1.8 m (5.91 ft) length
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
CONVERSION ADAPTER 9199
Receiving side banana (female), output BNC (male)
*For reference only. Please purchase locally.
Thermocouple
* Only the small terminal types can be used.
* The 9323 is not required for the small-terminal types 9327, 9320-01, 9321-01 and MR9321-01.
LOGIC PROBE 9320-01
• 4 channels for contact voltage signals • 500ns response • Miniature terminal type
LOGIC PROBE MR9321-01
• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type
CONVERSION CABLE 9323
• Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x. *The separately available Conversion Cable CT9900 is required in order to use a sensor with PL23 (10-pin) terminal.
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x. *The separately available Conversion Cable CT9900 is required in order to use a sensor with PL23 (10-pin) terminal.
CONVERSION CABLE CT9900
Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x. *The separately available Conversion Cable CT9900 is required in order to use a sensor with PL23 (10-pin) terminal.
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
SENSOR UNIT CT9557
• 4 channels, ±0.06% DC accuracy • Waveform, total waveform, and total RMS output
Connecting to the MR8880/MR8875/MR8870
• High-precision current sensor (ME15W) + CT9555 + BNC cable → MR8875
• High-precision current sensor (PL23) + CT9900 + CT9555 + BNC cable → MR8875
The CM7290 (available separately) is required in order to use these current sensors.
DISPLAY UNIT CM7290
• Pair with CT7000 series • DCA, ACA, (DC+AC)A, frequency • WAVE, RMS, PEAK, Hz output
OUTPUT CORD L9095
Connect to BNC terminal, 1.5 m (4.92 ft) length
DISPLAY UNIT CM7291 (Bluetooth®)
• Bluetooth(R) wireless technology • Pair with CT7000 series • DCA, ACA, (DC+AC)A, frequency • WAVE, RMS, PEAK, Hz output
*For commercial power lines, 50/60 Hz
CLAMP ON PROBE 9018-50
• 40 Hz to 3 kHz, ±1.5% accuracy • 10 to 500A AC • Max. 650 A rms continuous input
AC FLEXIBLE CURRENT SENSOR CT9667
• 10 Hz to 20 kHz, ±2% accuracy • Rated 5000 A/ 500 A AC
*For commercial power lines, 50/60 Hz
CONVERSION ADAPTER 9199
Receiving side banana (female), output BNC (male)
AC ADAPTER 9445-02
For USA, 100 to 240 V AC, 9 V/ 1 A
AC ADAPTER 9445-03
For EU, 100 to 240 V AC, 9 V/ 1 A
WAVE PROCESSOR 9335
• For the Memory HiCorder • Convert data, print and display waveforms
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
*Z1002 is a bundled accessory
AC ADAPTER Z1002
For main unit, 100 to 240 V AC
BATTERY PACK Z1003
NiMH, Charges while installed in the main unit
CARRYING CASE C1004
For the MR8875, includes compartment for options, hard trunk type
How to Test Capacitor Durability
Stress Measurment in Finished Vehicles [574KB]
High-resolution and Multi-force Component Recording
Measure Minute Voltage Waveforms of Devices, Superconducting Materials and Contacts
Measure the Current Consumption of Portable Devices such as Smartphones [305KB]
Development and Evaluation of Electric Vehicle (EV) Quick Chargers
Connectable Products of the Non-Contact CAN Sensor SP7001/SP7002
No results were found.