Exclusive Academic Offer >

MEMORY HiLOGGER

8423

600-channel Data Logger with 10ms Sampling

Hioki Memory HiLoggers are high-speed data loggers for recording multiple chanels of voltage, temperature, resistance, humidity, rotation, and pulse signals, providing complete isolation within channel sets. The 8423 with optional input modules log data at 10ms speeds across up to 600 simultaneously, and is configurable and controllable using a PC. Key Features • Capture data with 15 to a maximum of 600 channels • Send data to the PC in real time • Isolated to sustain up to 600 V between modules and earth • USB 2.0, LAN 100BASE-TX, store to 1GB PC Card • Simultaneous fast- and low-speed sampling allows for media storage space efficiency



Model No. (Order Code)

8423 Main unit only

Note: 8423 cannot operate alone. You must install one or more optional input modules in the unit. Thermocouples are not provided by HIOKI, and must be purchased from a separate vendor.

GOOD DESIGN
Guarantee3years
LAN
USB2
CE

Introducing a multichannel logger that can be expanded to accommodate various applications

The 8423 can be expanded with up to eight input modules. Four different types of module can be mixed and matched to accommodate specific applications. Adding an input module is easy thanks to one-touch installation. And since the 8423 can be mounted on industry-standard DIN rails, it’s ideal for use in embedded and rack-mounted applications.


Introducing a multichannel logger that can measure up to 40 modules (600 channels)

A single 8423 can be expanded with up to eight input modules (for a total of 120 channels). Those eight modules constitute one system, and the product can be expanded to include up to five systems (providing the ability to measure 600 channels). What’s more, data can be collected from all 600 channels in as little as 10 msec, making the 8423 ideal for use in measurement applications that involve rapid fluctuations in load, for example hybrid vehicles.


All-Channel Synchronous Measurement Capability

When measuring up to 120 channels on combined modules, all input channels are sampled synchronously. When multiple 8423s are connected via LAN or USB for measuring up to 600 channels, the sampling of each instrument in the system can be synchronized using optional Connection Cable Model 9683. As well as PC-based data collection, measurement start and stop can be controlled by the [START/MARK] and [STOP] keys on a master 8423. Note: Any 8423 may be designated as the master. Only the initial acquisition criteria setting needs to be performed on a PC via USB or LAN.


Isolated to sustain up to 600 V between modules and earth

With all channels isolated and a 600V AC/DC maximum rated voltage to earth, even when the common mode voltage increases as is common with layered batteries, the voltage of each individual battery cell can be safely measured.


Included PC application with measurement and analysis functionality

The supplied Logger Utility software enables processing of measurement data on a PC. Use the supplied Logger Utility software to record data on a PC in real-time. View past data during recording. Connect the PC to the HiLOGGER using USB or via LAN.


Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

No. of connectable unitsMaximum 8 units (total 120 channels), Bundle 8 modules together to achieve a 120-channel system, Bundle 5 systems together to enable a maximum of 600 channels of simultaneous recording
Measurement parameters Model 8948[No. of channels] 15 analog channels, isolated scanning method input (2 terminals: M3 screw type)
[Voltage measurement range] ±150 mV to ±100 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 100 VDC, between channels: 200 VDC, to earth: 600 VAC/DC
[Temperature range] -200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
Measurement parameters Model 8949[No. of channels] 15 analog channels, isolated scanning method input (4 terminals: push-button type) (not isolated between channels at resistance temperature sensor & humidity sensor)
[Voltage measurement range] ±150 mV to ±60 V, 1-5V, Max. resolution 5 µV, Max. allowable input: 60 VDC, between channels: 120 VDC, to earth: 600 VAC/DC
[Temperature range] −200˚C to 2000˚C (depend on the sensor), thermocouples (K, J, E, T, N, R, S, B, W), Max. resolution 0.01˚C
[Resistance temperature sensor range] −200˚C to 800˚C, (Pt 100, JPt 100), Max. resolution 0.01˚C
[Humidity] 5.0 to 95.0% rh, (use with optional sensor 9701), resolution 0.1% rh
Measurement parameters Model 8996[No. of channels] 15 channels, digital/pulse input (2 terminals: M3 screw type, CH1-5, CH6-10, CH11-15 are common GND, No-voltage ‘a’ contact, open collector or voltage input)
[Totalized pulses] 0 to 1000M pulse, Max. resolution 1 pulse
[Rotation count] 0 to 5000/n (r/s), Resolution 1/n (r/s) *n = pulses per rotation (1 to 1,000)
[Digital input] Record ON/OFF digital signal per interval
[Max. allowable input] 50 VDC, between channels: 33 VACrms or 70 VDC, to earth: 600 VAC/DC, (Upper limit voltage that does not cause damage when applied between CH1-5, CH6-10, CH11-15 each channel and chassis, and between each UNITs)
Recording intervals10 ms to 1 hr, 19 ranges (5s to 1hr when combined with humidity measurement), Dual sampling: Recording intervals can be specified for every input module (high-speed and low-speed)
FunctionMeasurement data are saved to the CF Card in real time, Trigger function, Digital filter (Input unit), Alarm output (use with the Alarm unit 8997), Data acquisition is controlled by the PC data acquisition program, FTP server function, HTTP server function
InterfaceLAN: supports 100Base-TX, USB: Ver 2.0, mini-B receptacle, CF card slot
Power supplyUsing the AC adapter 9418-15 (100 to 240 V, 50/60 Hz), 55 VA Max. (include AC adapter), 20 VA Max. (main unit only) (when connected with 8 units),
External DC Power: 9.6 V to 15.6 VDC, 20 VA Max. (when connected with 8 units) (Please contact HIOKI for connection cord)
Dimensions and mass67 mm (2.64 in) W × 133 mm (5.24 in) H × 125 mm (4.92 in) D, 600 g (21.2 oz) (main unit 8423 only)
AccessoriesQuick start manual × 1, Instruction manual × 1, AC adapter 9418-15 × 1, USB cable × 1, CD-R (data collection software “Logger Utility”) × 1, Connector cover × 1, Ferrite clamp × 1, Connection plate × 1

■ Combination status with LabVIEW or MATLAB script

Compatible modelsLabVIEWMATLAB script
8423OKN/A

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

Registration Open

ECCE 2019 - Baltimore, Maryland

Sep 29, 2019 - Oct 3, 2019

Catalogs

Catalog: MEMORY HiLOGGER 8423 Download PDF  [4MB] English
Catalog: DATA LOGGER Selection Guide LR8431, LR8400 series, 8423, LR5000 series Download PDF  [5MB] English

User Guides

No results were found.

Manuals

If you can not download, log into your myHioki account to access more technical documents and information where available.


Instruction Manual English
Ver.09
Quick Start Manual English
Ver.07

Outline Drawings

If you can not download, log into your myHioki account to access more technical documents and information where available.



Ver.01

Technical Notes

No results were found.

Declaration of Conformity


Ver.07

Others

No results were found.

Options

Input/output modules

VOLTAGE/TEMP UNIT 8948

15-channels

UNIVERSAL UNIT 8949

15-channels

DIGITAL/PULSE UNIT 8996

15-channels

ALARM UNIT 8997

15-channels

Input options

Sensor guaranteed for 1 year.

Thermocouple
*For reference only. Please purchase locally.

HUMIDITY SENSOR 9701

1-channel, for Universal unit 8949

High voltage measurement

* Maximum input-to-ground rated voltages fall within these products’ specifications ranges (and do not affect the connected input units)

DIFFERENTIAL PROBE P9000

• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply

Learn more

AC ADAPTER Z1008

100 to 240V AC

Options for Differential Probes

Can also be used with accessories such as L4936/L4937/L4931 as available for other testers.

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

CONVERSION CABLE L1011

30 cm (0.98 ft) length, covert BNC to wire

CONVERSION CABLE L1011-10

2.4 m (7.87 ft) length, covert BNC to wire

Custom cable

*For P9000.

Inquire with your Hioki distributor.
(1) Bus powered USB cable
(2) USB(A)- Micro B cable
(3) 3-prong cable

Storage media

* PC CARD 2G 9830 : cannot use with the 8423 * Supplied with PC Card adapter

PC card precaution
Use only PC cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.

PC CARD 512M 9728

• 512 MB capacity • PC card adapter bundled

Learn more

PC CARD 1G 9729

• 1 GB capacity • PC card adapter bundled

Learn more

Other options

*9418-15 is supplied as standard

AC ADAPTER 9418-15

100 to 240V AC

CONNECTION CABLE 9683

For synchronization, cable length 1.5 m (4.92 ft)

For the PC

*LOGGER UTILITY is a bundled software

LOGGER UTILITY SF1000

• For the HIOKI Memory HiLoggers • The control of the measurement of loggers, real-time data collection • Wavefrorm display, data conversion, calculation, search, print

Learn more

LAN CABLE 9642

Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length

Images

*Click on the image to enlarge it.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List


​​