POWER QUALITY ANALYZER
PW3198
3-Phase 4-Wire Power Quality Analyzer Compliant to IEC61000-4-30 Class A Standards with Dynamic 1300V Range, Harmonic and Inter-harmonics Analysis Capabilities
Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The PW3198 is a power quality analyzer for monitoring and recording power supply anomalies, allowing their causes to be quickly investigated, and also for assessing power supply problems such as voltage drops, flicker, harmonics, and other electrical issues. Key Features • Verify power problems in accordance with the IEC61000-4-30 Class A standard • High accuracy and continuous gapless recording (V: ±0.1% of nominal voltage, A and W: ±0.2% rdg. ±0.1% f.s.) • CAT IV 600V - safe enough for incoming power lines • Broadband voltage range lets you measure even high-order harmonic components of up to 80 kHz • Wide dynamic range from low voltages up to 1300V (3P4W line-to-line voltage) • Maximum 6000V transient overvoltage up to 700kHz • LAN, USB and SD card interfaces • Optional GPS BOX for synchronizing multiple devices
| PW3198 | Main unit, clamp sensor is sold separately |
|---|---|
| PW3198-90 | Kit includes software the 9624-50 |
Note: Voltage can be measured with the main unit alone. An optional current sensor is necessary to measure current or power parameters. Use the PQA-HiView Pro 9624-50 (version 2.00 or later) with a PC to analyze the data collected to the SD card.
| Measurement line type | Single-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel (must be synchronized to reference channel during AC/DC measurement) |
|---|---|
| Voltage ranges | Voltage measurement: 600.00 V rms Transient measurement 6.0000 kV peak |
| Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use) |
| Power ranges | 300.00 W to 3.0000 MW (determined automatically based on voltage and current range in use) |
| Basic accuracy | Voltage: ±0.1% of nominal voltage Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy |
| Measurement items | 1. Transient over voltage : 2 MHz sampling 2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz 3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle Current (1/2) RMS: half-cycle calculation 4. Voltage swell, Voltage dips, Voltage interruption 5. Inrush current 6. Voltage waveform comparison 7. Instantaneous flicker value: As per IEC61000-4-15 8. Frequency: Calculated as 10 or 12 cycles,40 to 70 Hz 9. 10-sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz 10. Voltage waveform peak, Current waveform peak 11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor (negative-phase, zero-phase) 12. High-order harmonic component (voltage/ current): 2 kHz to 80 kHz 13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders 14. Harmonic voltage-current phase angle: 1th to 50 th orders 15. Total harmonic distortion factor (voltage/ current) 16. Inter harmonic (voltage/ current): 0.5 th to 49.5 th order 17. K Factor (multiplication factor) 18. IEC Flicker, Δ V10 Flicker |
| Record | 55 weeks (with repeated recording set to [1 Week], 55 iterations) 35 days (with repeated recording set to [OFF]) |
| Interfaces | SD/SDHC memory card, RS-232C, LAN (HTTP server funtion), USB2.0 |
| Display | 6.5-inch TFT color LCD (640 × 480 dots) |
| Power supply | AC Adapter Z1002 (12 V DC, Rated power supply 100 V AC to 240 V AC, 50/60 Hz) Battery Pack Z1003 (Ni-MH 7.2 V DC 4500 mAh) |
| Dimensions and mass | 300 mm (11.81 in) W × 211 mm (8.31 in) H × 68 mm (2.68 in) D (excluding protrusions), 2.6 kg (91.7 oz) (including battery pack) |
| Accessories | Instruction manual ×1, Measurement guide ×1, Voltage cord L1000 ×1 set (Red/Yellow/Blue/Gray, each 1, Black ×4, Alligator clip ×8), Spiral tube ×20, Input Cable Labels ×1, AC adapter Z1002 ×1, Strap ×1, USB cable (1 m 3.28 ft length) ×1, Battery pack Z1003 ×1, SD memory card 2GB Z4001 ×1 |
Log into your myHioki account to access more technical documents and information where available.
| No results were found. |
|
|
Nov 6, 2019 - Nov 8, 2019 | |
|
|
Sep 18, 2019 - Sep 20, 2019 | |
|
|
May 29, 2019 - May 31, 2019 |
| Catalog: PQA-HiVIEW PRO 9624-50 | Download PDF [1MB] |
English |
| Catalog: POWER QUALITY ANALYZER PW3198 | Download PDF [5MB] |
English |
| Guidebook for Power Quality Measurement | Download PDF [2MB] |
English |
If you can not download, log into your myHioki account to access more technical documents and information where available.
| Measurement Guide |
English |
Ver.00 | |
| Measurement Guide |
Simplified Chinese |
Ver.00 | |
| Measurement Guide |
Spanish |
Ver.00 | |
|
POWER QUALITY ANALYZER PW3198 [12MB] |
Instruction Manual |
English |
Ver.04 |
|
POWER QUALITY ANALYZER PW3198 [5MB] |
Instruction Manual |
Simplified Chinese |
Ver.03 |
|
POWER QUALITY ANALYZER PW3198 [6MB] |
Instruction Manual |
Spanish |
Ver.02 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
|
POWER QUALITY ANALYZER PW3198 [202KB] |
Ver.02 |
| No results were found. |
|
POWER QUALITY ANALYZER PW3198 [111KB] |
Ver.07 |
| POWER QUALITY ANALYZER PW3198 | Firmware | V1.08 |
| No results were found. |
For power or load current measurement
(1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)
CLAMP ON SENSOR 9669
• 40Hz to 5kHz • 1000 A AC rated input • φ 55 mm (2.17 in) Core dia.
CLAMP ON SENSOR 9695-02
• 40Hz to 5kHz • 50 A AC rated input • φ 15 mm (0.59 in) core dia.
CLAMP ON SENSOR 9695-03
• 40Hz to 5kHz • 100 A AC rated input • φ 15 mm (0.59 in) core dia.
AC FLEXIBLE CURRENT SENSOR CT9667
• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input
CONNECTION CABLE 9219
Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length
Caution: Up to 5 A on Model PW3198
*Not capable of power measurement
CLAMP ON LEAK SENSOR 9657-10
• 40 Hz to 5 kHz • Rated 5 A AC • φ 40 mm (1.57 in) core dia.
For clamp sensor
CLAMP ON ADAPTER 9290-10
• Primary 1000A, secondary 100A (1/10 ratio) output • Superior phase angle characteristics for power
*The AC/DC Auto-zero Current Sensor CT7731/CT7736/CT7742 cannot be used on its own with the PW3198. Be sure to use a set that includes the Display Unit CM7290, Output Cord L9095, and AC Adapter 9445-02 or 9445-03.
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
・ DC to 5 kHz (-3dB) ・ Rated 100 A AC/DC ・φ 33 mm (1.30 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
・ DC to 5 kHz (-3dB) ・ Rated 600 A AC/DC ・φ 33 mm (1.30 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
・ DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC ・φ 55 mm (2.17 in) core dia.
DISPLAY UNIT CM7290
• Use with CT7000 series • DCA, ACA, (DC+AC)A, frequency • WAVE, RMS, PEAK, Hz output
OUTPUT CORD L9095
Connect to BNC terminal, 1.5 m (4.92 ft) length
AC ADAPTER 9445-02
For USA, 100 to 240 V AC, 9 V/ 1 A
AC ADAPTER 9445-03
For EU, 100 to 240 V AC, 9 V/ 1 A
*The L1000 is bundled
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
MAGNETIC ADAPTER 9804-01
Attaches to the tip of cord, red ×1, φ11 mm (0.43 in)
MAGNETIC ADAPTER 9804-02
Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)
VOLTAGE CORD L1000
Red/ Yellow/ Blue/ Gray each 1, Black 4, 3m (9.84ft) length, Alligator clip ×8
WIRING ADAPTER PW9000
For three-phase 3-wire
WIRING ADAPTER PW9001
For three-phase 4-wire
*The Z1002, Z1003 are bundled
AC ADAPTER Z1002
For main unit, 100 to 240 V AC
BATTERY PACK Z1003
NiMH, Charges while installed in the main unit
*The Z4001 is bundled
SD Card Precaution
Use only the SD Card Z4001 sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.
SD MEMORY CARD 2GB Z4001
2 GB capacity
SD MEMORY CARD Z4003
8 GB capacity
CARRYING CASE C1001
Soft type, Includes compartment for options
CARRYING CASE C1002
Hard trunk type, Includes compartment for options
CARRYING CASE C1009
Bag type, Includes compartment for options
PQA-HiVIEW PRO 9624-50
• For PW3198, 3197, 3196 • Easy operation, analyze data on the PC • Convenient report creation function
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
GPS BOX PW9005
To synchronize the PQ3198 / PW3198 clock to UTC
Measure Transient Overvoltage Waveforms [1MB]
Measure Periodical Instantaneous Voltage Drops [1MB]
Test for Abnormal Waveforms when Switching to UPS Power
Inspect the Stress on Factory UPS Caused by Voltage Dips [1MB]
Checking the Amount of Electricity Sold in Photovoltaic (PV) Systems [1MB]
Measure the High-Order Harmonic Voltage and Current of Power Lines [1MB]
Power Quality Survey of Solar Power Generation Systems [115KB]
Measure the Noise Generated by Switching Power Factor Correction Capacitors
Measure the Transient Overvoltage in Glowing Fluorescent Lights [947KB]
Measure Lightning-induced Voltage Dips in a Low-Voltage Circuit [1MB]
Measure Voltage Drop Caused by Wiring Impedance [716KB]
No results were found.