Exclusive Academic Offer >

CLAMP ON POWER LOGGER

PW3360

Portable Power Loggers for Energy Audits and Energy Conservation

HIOKI Clamp On Power Meters are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3360 compact 3-Phase 4-Wire energy loggers monitor power demand and other power parameters to aid in energy audits and validate energy saving measures. Key Features • Supports single to three-phase, 4-wire circuits • Measure between 90V to 780V • Simultaneously measure up to three single-phase, 2-wire circuits (in the same power system) • Slim, compact design that can be placed anywhere • Store months of data on SD cards • The QUICK SET function guides you in making the right connections • Choose PW3360-21 for harmonic measurements up to the 40th order • WHM (watt-hour meter) connection checking function installed

Model No. (Order Code)

PW3360-20 English model, main unit only
PW3360-21 English model, with harmonic analysis function

Note: At least one optional current sensor is necessary to measure current or power parameters. To store measurement data, use only the guaranteed SD cards sold by HIOKI.

Guarantee3years
LAN
USB2
TrueRMS
SD
CE

Product Video


Navigate clamp-on power logger operation with graphical, easy-to-use displays of wiring procedures

The PW3360’s QUICK SET feature is an on-screen guide that walks you through the setup process, right up to starting measurement. Even if you’re unaccustomed to how clamp-on power loggers work, you’ll be able to easily configure and connect the instrument for 3-phase power measurement. In addition, by alerting you to any wiring mistakes, the device’s “wiring check” function serves to prevent measurement errors that are caused by undetected wiring mistakes.


Power logger functionality for displaying measurement results as a graph so you can review them at a glance

The PW3360 displays recorded measured values as a graph for convenient use in power management. In addition to instantaneous measured values, you can review maximum, minimum, and average values by moving the cursor on the demand and trend graph displays.


A portable power logger that’s small enough to use in a confined cubicle

This power logger is an essential tool for power-saving activities. Thanks to a compact design that weighs just 550 g, it’s easy to take into the field and install in confined locations.


Get results from the job site in real-time, GENNECT CROSS SF4000

Capture data on the PC while testing remotely


Learn more

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 1 year)

Measurement line & number of circuits50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
Measurement itemsVoltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power (with lag/lead display), apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand, pulse input
[PW3360-21 only]: Harmonic voltage level, harmonic current level, harmonic power level, content percentage, phase angle, total harmonic distortion (THD-F or THD-R), up to 40th order
Voltage ranges600 V AC (Effective measurement range: 90.00 V to 780.00 V)
Current ranges500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
Power ranges300.00 W to 9.0000 MW (depends on voltage/current combination and measured line type)
Basic accuracyVoltage : ±0.3% rdg. ±0.1% f.s
Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Active power : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy (at power factor = 1)
Display update rate0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
Save destinationSD memory card, or internal memory at real time
Data save interval1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Save itemsMeasurement value save: Average only / Average, Max./Min. value, [PW3360-21 only]: Harmonic data save: Average only / average, max./min. value in binary format, Screen copy: BMP form (saved every 5 min. at minimum interval time), Waveform save: Binary waveform data
InterfacesSD/SDHC memory card
LAN 100BASE-TX: HTTP server function, remote settings via communication program, data download
USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
Pulse output: proportional to active power consumption when measuring integral power consumption, Isolated open-collector signal
FunctionsConnection check, Quick Set navigation guide, clock, pulse input
Power supplyAC Adapter Z1006: (100 to 240 V AC, 50/60 Hz), 40 VA (including AC adapter)
Battery Pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 8 hours of continuous use (with back light off)
Dimensions and mass180 mm (7.09 in) W × 100 mm (3.94 in) H × 48 mm (1.89 in) D, 550 g (19.4 oz) without PW9002
180 mm (7.09 in) W × 100 mm (3.94 in) H × 67.2 mm (2.65 in) D, 830 g (29.3 oz) with PW9002
AccessoriesVoltage cord L9438-53 ×1 set, AC adapter Z1006 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip ×1 set: red, yellow, blue, white/two each, for color-coding clamp sensors, Spiral tubes for grouping clamp sensor cords ×5

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Catalogs

Catalog: CLAMP ON POWER LOGGER PW3360 Download PDF  [5MB] English
Catalog: GENNECT CROSS SF4000 Download PDF  [1MB] English

User Guides

How to Manage Your Power Efficiently Download PDF  [2MB] English

Manuals

Communications Manual English
Ver.03
Measurement Guide English
Ver.03
Measurement Guide Korean
Ver.01
Measurement Guide Spanish
Ver.01
Measurement Guide Indonesian
Ver.00
Instruction Manual English
Ver.06
Instruction Manual Korean
Ver.02
Instruction Manual Spanish
Ver.02

Outline Drawings


Ver.01

Ver.01

Ver.00

Technical Notes

No results were found.

Drivers, Firmware

USB driver (for PW3360/PW3365)  Freeware Version 2.0.0.9 
PW3360/PW3365 Auto Excel Graph Creation Application  Freeware Version 2.03.0 
PW3360/PW3365 Settings and Download Application  Freeware Version 2.03.0 
GENNECT Cross for Windows  Freeware V2.11 
CLAMP ON POWER LOGGER PW3360-20,PW3360-21  Firmware V3.20 

Others

No results were found.

Options

Current measurement

For power or load current measurement

(1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)

CLAMP ON SENSOR 9660

• 40Hz to 5kHz • 100 A AC rated input • φ 15 mm (0.59 in) core dia.

Learn more

CLAMP ON SENSOR 9661

• 40Hz to 5kHz • 500 A AC rated input • φ 46 mm (1.81 in) core dia.

Learn more

CLAMP ON SENSOR 9669

• 40Hz to 5kHz • 1000 A AC rated input • φ 55 mm (2.17 in) Core dia.

Learn more

CLAMP ON SENSOR 9694

• 40Hz to 5kHz • 5A AC rated input • φ 15 mm (0.59 in) core dia.

Learn more

CLAMP ON SENSOR 9695-02

• 40Hz to 5kHz • 50 A AC rated input • φ 15 mm (0.59 in) core dia.

Learn more

CLAMP ON SENSOR 9695-03

• 40Hz to 5kHz • 100 A AC rated input • φ 15 mm (0.59 in) core dia.

Learn more

AC FLEXIBLE CURRENT SENSOR CT9667

• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input

Learn more

CONNECTION CABLE 9219

Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length

Leak current

For leak current measurement (not capable of power measurement)

Caution: Up to 5 A on Model PW3360

CLAMP ON LEAK SENSOR 9657-10

• 40 Hz to 5 kHz • Rated 5 A AC • φ 40 mm (1.57 in) core dia.

Learn more

CLAMP ON LEAK SENSOR 9675

• 40 Hz to 5 kHz • Rated 5 A AC • φ 30 mm (1.18 in) core dia.

Learn more

Adapter

For clamp sensor

CLAMP ON ADAPTER 9290-10

• Primary 1000A, secondary 100A (1/10 ratio) output • Superior phase angle characteristics for power

Learn more

Voltage measurement

*L9438-53 is bundled with the PW3360-20/-21

MAGNETIC ADAPTER 9804-01

Attaches to the tip of cord, red ×1, φ11 mm (0.43 in)

MAGNETIC ADAPTER 9804-02

Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)

VOLTAGE CORD L9438-53

Black/ Red/ Yellow/ Blue, 3 m (9.84 ft) length, Alligator clip ×4

PATCH CORD L1021-01

Banana branch-banana, Red: 1, Cable length: 0.5 m, For branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V

PATCH CORD L1021-02

Banana branch-banana, Black: 1, Cable length: 0.5 m, For branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V

Storage media

SD Card Precaution

Use only SD Cards sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.

SD MEMORY CARD 2GB Z4001

2 GB capacity

SD MEMORY CARD Z4003

8 GB capacity

Power supply

*Z1006 is bundled with the PW3360-20/-21.

Model 9459 is a replacement battery pack included with the Battery Set PW9002.

BATTERY PACK 9459

NiMH, Charges while installed in the main unit

BATTERY SET PW9002

Battery case and Battery Pack 9459 Set

VOLTAGE LINE POWER ADAPTER PW9003

For PW3360, supplies power from measurement lines, up to 240V AC

AC ADAPTER Z1006

100 to 240 V AC

Other options

CARRYING CASE C1005

For PW3360/3365 series, for storing options

PC peripherals

POWER LOGGER VIEWER SF1001

• Easy graphical processing of measurement data saved with the PW3360/3365 series, 3169 series on a PC

Learn more

GENNECT CROSS SF4000

• Software automatically recognizes LAN-connected measuring instrument • Display acquired data as graphs in real-time • Windows compatible

Learn more

LAN CABLE 9642

Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor