CLAMP ON POWER HiTESTER
3169
Demand Measurement up to 4 Circuits and Simultaneous Harmonics Analysis
Hioki portable power meters and analyzers are best in class power measuring instruments for measuring single to three-phase lines with a high degree of precision and accuracy. The 3169 is clamp on power meters designed to measure demand and harmonics, which are important for energy management, as well as basic electrical parameters such as voltage, current, power, power factor, and integrated power (watthours). Key Features • Simultaneously measure demand and harmonic waveforms that share the same voltage line over 4-circuits • Data can be saved onto a PC card • High-speed and continuous processing to measure individual waveforms • High-speed D/A output for analog graph recording (Model 3169-21)
3169-20 | Main unit, clamp sensor is sold separately |
---|---|
3169-21 | With D/A output function model |
Note: Optional current sensor is necessary to measure current or power parameters. To store measurement data, use only the guaranteed PC cards sold by Hioki.
In addition to performing simultaneous measurement for up to four systems (single-phase, 2-wire) with a common voltage, you can set the current range individually for each system. Setting the most suitable current range for both large and small loads allows you to acquire more accurate measurements.
Measurement line & number of circuits | Single-phase 2-wires (4 circuits), Single-phase 3-wires (2 circuits), Three-phases 3-wires (2 or 1 circuit), and Three-phases 4-wires (1 circuit) Note: 50 or 60 Hz, and that share the same voltage line |
---|---|
Measurement items | Voltage, Current, Active/ reactive/ apparent power, Active/ reactive power integration, Power factor, Frequency, Harmonic waveform value (up to 40th order) |
Measurement range | [Voltage] 150.00 V to 600.00 V AC, 3 ranges, [Current] 500.00 mA to 5.0000 kA AC (depends on current sensor in use), [Power] 75.000 W to 900.00 kW (depends on combination of voltage, current range, and measurement line) |
Basic accuracy | AC Voltage: ±0.2 % rdg. ±0.1 % f.s. AC Current: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy (at power factor = 1) Clamp on sensor 9661: ±0.3 % rdg. ±0.01 % f.s. (different from each sensor models) |
Measurement method | Digital sampling, PLL synchronization or 50/60 Hz fixed clock |
Display refresh rate | 2 times /sec (except when a PC card accessing, or RS-232C communications) |
Data save interval | Standard interval: 1 sec to 30 sec, 1 minute to 60 minutes, 13 selects Fast interval: A single waveform, or 0.1, 0.2, or 0.5 sec (at instant value only) |
Frequency characteristics | Fundamental waveforms up to the 50th order ±3% f.s. + measurement accuracy (of a 45 to 66 Hz fundamental waveform) |
Other functions | Error connect check, language selection, display hold, setting backup, power shut off management, key lock, [3169-21 only] D/A output 4 channels, (±5 V DC f.s.) |
Power supply | 100 to 240 V AC, 50/60 Hz, 30 VA max. |
Dimensions and mass | 210 mm (8.27 in)W × 160 mm (6.30 in)H × 60 mm (2.36 in)D, 1.2 kg (42.3 oz) |
Accessories | Voltage cord L9438-53 ×1 (Black/ Red/ Yellow/ Blue, 3 m (9.84 ft) length, Alligator clip ×4), Power cord ×1, Instruction manual ×1, Quick start manual ×1, CD-R ×1 (RS-232C interface operating manual) ×1, Input cord label ×1, Connection cable 9441 ×1 (for the 3169-21 only) |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Catalog: CLAMP ON POWER HiTESTER 3169 | Download PDF [1MB] |
English |
Voltage, Current, and Power Measurement for Cycle-controlled Loads, Phase-controlled Loads, and Inverters | Download PDF [558KB] |
English |
If you can not download, log into your myHioki account to access more technical documents and information where available.
Notes on CD-R Usage |
Japanese English |
Ver.06 | |
Quick Start Manual |
English |
Ver.07 | |
CLAMP ON POWER HiTESTER 3169-20,3169-21 [2MB] |
Instruction Manual |
English |
Ver.11 |
CLAMP ON POWER HiTESTER 3169-20,3169-21 [576KB] |
RS-232C Instruction Manual |
English |
Ver.04 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
CLAMP ON POWER HiTESTER 3169 [97KB] |
Ver.00 |
CLAMP ON POWER HiTESTER 3169-01 [96KB] |
Ver.00 |
No results were found. |
CLAMP ON POWER HiTESTER 3169-20,3169-21 [119KB] |
Ver.13 |
RS-232C COMMUNICATION PROGRAM FOR CLAMP ON POWER HiTESTER 3169-20/21 | Freeware | Version 0.02 |
No results were found. |
For power or load current measurement
(1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3 phase measurements)
CLAMP ON SENSOR 9669
• 40Hz to 5kHz, ±1.0% accuracy • Rated 1000 A AC, 0.5 mV/A output rate
CLAMP ON SENSOR 9695-02
• 40Hz to 5kHz, ±0.3% accuracy • Rated 50 A AC, 10 mV/A output rate
CLAMP ON SENSOR 9695-03
• 40Hz to 5kHz, ±0.3% accuracy • Rated 100 A AC, 1 mV/A output rate
AC FLEXIBLE CURRENT SENSOR CT9667
• 10 Hz to 20 kHz, ±2% accuracy • Rated 5000 A/ 500 A AC
CONNECTION CABLE 9219
Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length
For clamp sensor
CLAMP ON ADAPTER 9290-10
• Primary 1000A, secondary 100A (1/10 ratio) output • Superior phase angle characteristics for power
*The L9438-53 is bundled
MAGNETIC ADAPTER 9804-01
Attaches to the tip of cord, red ×1, φ11 mm (0.43 in)
MAGNETIC ADAPTER 9804-02
Attaches to the tip of cord, black ×1, φ11 mm (0.43 in)
VOLTAGE CORD L9438-53
Black/ Red/ Yellow/ Blue, 3 m (9.84 ft) length, Alligator clip ×4
PATCH CORD L1021-01
Banana branch-banana, Red: 1, 0.5 m (1.64 ft) length, for branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V
PATCH CORD L1021-02
Banana branch-banana, Black: 1, 0.5 m (1.64 ft) length, for branching from the L9438s or L1000s, CAT IV 600 V, CAT III 1000 V
POWER LOGGER VIEWER SF1001
• For PW3360, PW3365 and 3169 series • Trend graph presentation • Summary, daily, weekly, and monthly reports and printing
* PC CARD 2G 9830, PC CARD 1G 9729 : cannot use with the 3169-20, 3169-21 * Supplied with PC Card adapter
PC Card Precaution
Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.
RECORDING PAPER 1196
112 mm (4.41 in) × 25 m (82.03 ft), 10 rolls/set
PRINTER 9442
For printing numerical values 112 mm (4.41 in) paper width, not CE marked
AC ADAPTER 9443-02
For the Printer 9442, EU type
RS-232C CABLE 9721
Mini DIN 9pin to D-sub 9pin, straight, 1.5 m (4.92 ft) length
*The 9441 is bundled with the 3169-21
CONNECTION CABLE 9440
For external control, 2 m (6.56 ft) length
CONNECTION CABLE 9441
For D/A output, 2 m (6.56 ft) length
RS-232C CABLE 9612
For the PC, Mini DIN 9pin to D-sub 9pin, cross, 1.5 m (4.92ft) length
CARRYING CASE 9720-01
Soft type, Includes compartment for options, for the 3169 series
No results were found.