Hioki compact 1 or 2-channel data loggers feature a 60,000 data set/channel memory to measure temperature, humidity, voltage or instrumentation signals. The LR5001 logs temperature and humidity over 2 channels in as fast as 1 second intervals. Key Features • Easily mount the light-weight , pocket-sized loggers in tight spaces • Easy-to-see dual display • Transfer data to PC even during recording • Replace batteries while recording (30 second limit) Note: Recording is interrupted during battery replacement if the battery is very weak. After batteries are replaced, recording resumes automatically. Previously recorded data is not lost during battery replacement. • 7 times the memory capacity than predecessor (Record 60,000 data per channel) • Record without missing fluctuations in STAT mode • Measurement data is preserved even after the battery dies • Worry-free backup preserves recorded data even if a new measurement is started by mistake
LR5001 | Temperature / Humidity each 1ch |
---|
Note: Communication Adapter LR5091 or Data Collector LR5092-20 is necessary to transfer data from a LR5000 series Logger to a PC
Measurement items | Temperature 1 ch and Humidity 1 ch (Requires included or optional humidity sensor) |
---|---|
Measurement range | Temperature: -40.0 to 85.0 °C, Humidity: 0 to 100 % rh *at sensor environment |
Basic accuracy | [Temperature] : ±0.5 °C (main unit + sensor accuracy, at 0.0 to 35.0 °C) [Humidity] : ±5 % rh (main unit + temperature / humidity sensor LR950x combination, at 20 to 30 °C / 10 to 50 % rh) Note: Basic accuracy is typical value, refer to the detailed catalog |
Storage capacity | Instantaneous value mode: 60,000 data/ch, Statistical value mode: 15,000 data/ch |
Recording interval | 1 to 30 sec., 1 to 60 min., 15 selections |
Recording modes | Instantaneous recording: at every recording interval Statistical value recording: Measure at one second intervals, and record the instantaneous, maximum, minimum, and average values within every recording interval |
Recording methods | One-time recording: Stop recording when the memory capacity is full Endless recording: Continue recording even when the memory capacity is full (old data is overwritten) Start: Logger button operation or scheduled time Stop: Logger button operation or scheduled time, or auto-stop when the memory capacity is full (at one-time recording) |
Other functions | Always backs up last recorded data; backs up recorded data and setting conditions when battery power is low Note: After batteries are replaced within 30 seconds, recording resumes automatically (Recording is interrupted during battery replacement) |
Waterproof and dust-proof | IP54 (EN60529) (with sensor connected, but not including sensor tip) |
Interfaces | Infrared optical communications with LR5091, LR5092-20 |
Power supply | LR6 (AA) Alkaline battery × 1, Battery life: Approx. 3 months (Instantaneous recording, with 1-minute interval and auto power saving, at 20 °C), Approx. 20 days (Instantaneous recording, with 1-second interval at 20 °C) |
Dimensions and mass | 79 mm (3.11 in) W × 57 mm (2.246 in) H × 28 mm (1.10 in) D, 105 g (3.7 oz) |
Accessories | LR6 (AA) Alkaline battery (built-in internal) × 1, Humidity Sensor LR9504 × 1, Instruction manual × 1, Operation guide × 1, Kickstand × 1 |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
No results were found. |
Catalog: DATA LOGGER LR5000 Series | Download PDF [5MB] |
English |
No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
Operation Manual |
Simplified Chinese |
Ver.01 | |
Operation Manual |
English |
Ver.02 | |
Instruction Manual |
English |
Ver.03 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
HUMIDITY LOGGER LR5001 [55KB] |
Ver.04 |
HUMIDITY LOGGER LR5001-20 [56KB] |
Ver.02 |
No results were found. |
|
Ver.05 |
LR5000 Data Logger Series Firmware Upgrade | Firmware | V1.05(LR5051) |
No results were found. |
For data acquisition to PC
DATA COLLECTOR LR5092
• Collect up to 60,000 data x 16 channels from LR5000 series loggers • Transfer data from logger to PC • Transfer setting/clock data from PC to logger • Free bundled software
COMMUNICATION ADAPTER LR5091
• Transfer data from logger to PC • Transfer setting/clock data from PC to logger • Free bundled software
WALL-MOUNTED HOLDER LR9901
Not compatible with Model LR5051
MAGNETIC STRAP Z5004
LR9504 is bundled accessory
HUMIDITY SENSOR LR9501
1 m (3.28 ft) length Temperature range: -40 to 85 ˚C Humidity range: 0 to 100 % rh Response time: 300 seconds (90 % response time) Waterproof: None Sensor size: 13×30 mm (0.51×1.18 in)
HUMIDITY SENSOR LR9502
5 m (16.41 ft) Temperature range: -40 to 85 ˚C Humidity range: 0 to 100 % rh Response time: 300 seconds (90 % response time) Waterproof: None Sensor size: 13×30 mm (0.51×1.18 in)
HUMIDITY SENSOR LR9503
10 m (32.81 ft) Temperature range: -40 to 85 ˚C Humidity range: 0 to 100 % rh Response time: 300 seconds (90 % response time) Waterproof: None Sensor size: 13×30 mm (0.51×1.18 in)
HUMIDITY SENSOR LR9504
40 mm (1.57 in) Temperature range: -40 to 85 ˚C Humidity range: 0 to 100 % rh Response time: 300 seconds (90 % response time) Waterproof: None Sensor size: 13×30 mm (0.51×1.18 in)
Temperature/Humidity Control during Cargo Transportation [1MB]
Temperature and Humidity Changes in Chemical Storage [3MB]
Improve Air-conditioner Operating Conditions
Monitor for Differences in the Temperature/Humidity [698KB]
Analyze the Effects of Rooftop Gardening [584KB]
Measure the Effect of Humidity on Sea Cargo [440KB]
Managing the Temperature/Humidity during the Curing of Concrete
No results were found.