DIGITAL MULTIMETER

DT4282

World's Premier Digital Multimeter! Superior Accuracy and High Response, Topped with Safety Terminal Shutters

The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket types. The DT4282 is a high-precision 60,000 count digital multimeter with direct 10A input and all of the functions and features required for advanced testing in laboratories and R&D. CAT IV 600 V, CAT III 1000 V Key Features • 60000 count, 5-digit display, high-resolution measurements • ±0.025% DC V basic accuracy, wide 20 Hz to 100 kHz AC V frequency characteristics • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms) • Includes multiple measurement functions such as DC+ACV, temperature, capacitance, and frequency • Terminal shutter mechanism (prevents erroneous test lead insertion) • Dual display lets you check voltage and frequency simultaneously • Magnetic strap (Optional) • Rear kickstand • Store probes at the back of the tester • Identify excessively high input with a red screen backlight • Robust design capable of withstanding a drop from a height of 1 m • USB communications function supports PC measurements (optional) • Broad -15 (5°F) to 55°C (131°F) operating temperature range

Model No. (Order Code)

DT4282 10 A direct input

予備
Guarantee3years
USB2
Option
TrueRMS
CE
DROPPROOF

Video on how to use digital multimeters

This video introduces how to use the DT4280 series of digital testers as well as some of the instrument’s featured functionality. Hioki testers are engineered to help professional electricians do their jobs safely and quickly.


The ultimate digital multimeter, ideal for use R&D applications

The DT4282, which is part of Hioki’s DT4280 series of high-end digital multimeters, is designed for use in laboratories and R&D applications where you wish to measure a wide variety of parameters. ・ DC current 600.00μA / 6000.0μA / 60.000mA / 600.00mA /6.0000A / 10.000A ・ AC current 600.00μA / 6000.0μA / 60.000mA / 600.00mA /6.0000A / 10.000A ・ Conductance 600.00nS


Measure output voltage on the secondary sides of inverters by eliminating harmonic components

Accurately measure the fundamental wave alone by eliminating harmonic components with the DMM’s low-pass filter function.


Measure ripple voltage of DC charging systems

You can measure ripple voltage with a superposed DC signal by using peak value measurement and DC + AC voltage measurement.


Percentage display for 4 to 20 mA instrumentation signals

The digital multimeters can convert and display instrumentation signals of 4 to 20 mA or 0 to 20 mA representing properties such as temperature, pressure, and flow rate from a transducer or other device that converts sensor data into an electrical signal.


600.00 μA range for measuring very low currents used by gas-burning devices

Accurately measure the very low currents such as burner flame currents.


True RMS measurement for accurate measurement of even distorted current waveforms

Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement. The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability.


Measurement data can be downloaded to, reviewed on, and saved to a computer.

If you connect the DT4282 to a computer with the optional Communication Package DT4900-01, you can graph data stored in the instrument’s internal memory and display measurement results in real time on the computer. In addition, displayed measured values can be saved (in text format). *Use of optical communications keeps the computer and instrument electrically isolated to ensure safety. *The computer and multimeter are electrically isolated by means of optical communications so that data can be sent without concern for electrical hazards.


Designed and manufactured in Japan to ensure high quality and guaranteed with a 3-year warranty for peace of mind

All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.


Safe measurement requires use of an instrument that suits the measurement location.

To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.


Basic specifications (Accuracy guaranteed for 1 year)Regarding DMM Accuracy Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information. * Zero-suppression: For small inputs below the guarantee range, zero is effectively displayed

DC voltage60.000 mV to 1000.0 V, 6 ranges, Basic accuracy: ±0.025 % rdg. ±2 dgt.
AC Voltage* 60.000 mV to 1000.0 V, 6 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.2 % rdg. ±25 dgt. (True RMS, crest factor 3)
DC + AC Voltage* 6.0000 V to 1000.0 V, 4 ranges, Frequency characteristics: 20 Hz - 100 kHz
Basic accuracy 45 - 65 Hz : ±0.3 % rdg. ±30 dgt. (True RMS, crest factor 3)
Resistance60.000 Ω to 600.0 MΩ, 8 ranges, (Conductance: 600.00 nS, DT4282 only)
Basic accuracy: ±0.03 % rdg. ±2 dgt.
DC current600.00 μA to 10.000 A, 6 ranges, Basic accuracy: ±0.05 % rdg. ±5 dgt.
AC Current* 600.00 μA to 10.000 A, 6 ranges,
Basic accuracy 45 - 65 Hz : ±0.6 % rdg. ±5 dgt. (True RMS, crest factor 3)
Frequency characteristics: 20 Hz - 20 kHz (at 600 μA to 600 mA range)
AC Current* (use with Clamp on probes) N/A
PeakDC V measurement: Signal width 4 msec or more (single), 1 msec or more (repeated)
AC V, DC/AC A measurement:
Signal width 1 msec or more (single), 250 μsec or more (repeated)
C (capacitance)1.000 nF to 100.0 mF, 9 ranges, Basic accuracy: ±1.0 % rdg. ±5 dgt.
Continuity CheckContinuity threshold: 20/50/100/500 Ω, Response time: 10 ms or more
Diode testOpen terminal voltage: 4.5 V or less, Testing current 1.2 mA or less, Threshold of forward voltage: 0.15 V to 3 V, seven stages
FrequencyAC V, DC+AC V, AC A measurement, at pulse width 1 μs or more (50 % duty ratio)
99.999 Hz (0.5 Hz or more) to 500.00 kHz, 5 ranges, ±0.005 % rdg. ±3 dgt.
dB conversionStandard impedance setting (dBm), 4 Ω to 1200 Ω, 20 stages
Display dB conversion value of AC voltage (dBV)
Temperature (thermocouples)K: -40.0 °C to 800.0 °C (-40.0 °F to 1472.0 °F)
Add accuracy of the Thermocouple probe to main unit accuracy: ±0.5 % rdg. ±3 °C
Other functionsFilter function (Remove harmonic noise, use only at 600 VAC, 1000 VAC ranges), Display value hold, Auto hold, Max/Min value display, Sampling select, Relative display, Measurement memory (400 data), Auto-power save, USB communication (option), 4-20 mA % conversion
DisplayMain and Sub displays: 5-digits LCD, max. 60000 digits
Display refresh rates5 times/s (Capacitance measurement: 0.05 to 2 times/s, depending on measured value, Temperature: 1 time/s )
Power supplyLR6 (AA) alkaline batteries ×4, Continuous use: 100 hours
Dimensions and mass93 mm (3.66 in) W × 197 mm (7.76 in) H× 53 mm (2.09 in) D, 650 g (22.9 oz) (with test leads holder and batteries)
AccessoriesTest Lead L9207-10 ×1, Instruction Manual ×1, LR6 Alkaline Battery ×4

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Seminar Schedule

No results were found.

Catalogs

Catalog: COMMUNICATION PACKAGE (USB) DT4900-01 Download PDF  [1MB] English
Catalog: DIGITAL MULTIMETER DT4200 Series Download PDF  [5MB]
e-BOOK
English

User Guides

DMM series selection guide Download PDF  [580KB] English

Manuals

Instruction Manual Spanish  Ver.04
Instruction Manual English
Ver.07
Instruction Manual French  Ver.02
Instruction Manual Simplified Chinese  Ver.04
Instruction Manual Korean  Ver.04

Outline Drawings


Ver.00
No results were found.

Technical Notes

Declaration of Conformity


Ver.04

Drivers, Firmware

DMM Communicator for DT4200s  Freeware Version 2.10 
USB Driver (DT4200 series, 3800 series, 7016, 3554,ST5540,ST5541,BT4560)  Freeware Version 1.12.0 

Others

No results were found.

Options

Test leads

Options for the L9207-10 (L9207-10 is a bundled accessory)

CONTACT PIN SET L4933

Attaches to the tip of the Test Lead L9207-10/DT4911, L9206, 70V DC/ 33V AC

SMALL ALLIGATOR CLIP SET L4934

Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V

TEST LEAD L9207-10

90 cm (2.95 ft) length

Options for Test leads

Options for the L4930

GRABBER CLIP 9243

Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V

CONNECTION CABLE SET L4930

1.2 m (3.94 ft) length

EXTENSION CABLE SET L4931

Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length

TEST PIN SET L4932

Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V

ALLIGATOR CLIP SET L4935

Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V

BUS BAR CLIP SET L4936

Attaches to the tip of the banana plug cable, CAT III 600V

MAGNETIC ADAPTER SET L4937

Attaches to the tip of the banana plug cable, CAT III 1000V

TEST PIN SET L4938

Attaches to the tip of the banana plug cable, CAT III 600V

BREAKER PIN SET L4939

Attaches to the tip of the banana plug cable, CAT III 600V

Temperature measurement

THERMOCOUPLES(K) DT4910

K type, tip exposed, 0.3 mm (0.01 in) diameter, 80 cm (2.62 ft) length, -40 to 260 °C (-40 to 500 °F), tolerance ±2.5 °C

Other options

CARRYING CASE C0202

COMMUNICATION PACKAGE (USB) DT4900-01

For DT4280s/4250s, compatible to Windows 8.1/ 8/ 7/ Vista

MAGNETIC STRAP Z5020

Extra strength

Applications

No results were found.

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

     

    • email
    • Ask Online
  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List