CLAMP ON POWER LOGGER

PW3365

Eliminate the Risk of Short-Circuits and Electrical Accidents

Hioki Clamp On Power Meters are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3365 power logger takes safety and convenience one step further by being the world’s first non-metallic contact power meter that utilizes completely covered voltage clips that can be attached to any part of a cable or busbar. Customers can now monitor power demand and other power parameters to aid in energy audits and validate energy saving measures without risk of short-circuit accidents, power interruptions, or bodily injury due to electrocutions. Key Features • Voltage measurement from the top of the cable, zero risk of short circuit • Supports single to three-phase, 4-wire circuits • Measure between 90V to 520V • Slim, compact design that can be placed anywhere • Store months of data on SD cards • The QUICK SET function guides you in making the right connections • WHM (watt-hour meter) connection checking function installed

Model No. (Order Code)

PW3365-20 English model, main unit only

Note: Clamp On Power Logger PW3365 by itself does not support current and power measurements. Current and power measurements require clamp on sensors, sold separately. Use only HIOKI SD cards guaranteed to work for saving measurement data (options, sold separately).

予備
Guarantee3years
LAN
USB2
TrueRMS
SD
CE

Award

• German Design Award Special 2016 (*For Voltage Sensor PW9020) • 2015 The Nikkan Kogyo Shimbun MACHINE DESIGN AWARD Distinctive Merit Award (* For PW3365)


Product Video


Safely and easily measure power without the need to shut off the circuit breaker first with a clamp-on power logger

Although technicians had to connect instruments to metal terminals in order to measure voltage when measuring power in the past, Hioki’s newly developed no-metal-contact voltage sensor makes it possible to measure voltage simply by clamping the sensor around an insulated wire. This approach completely eliminates the risk of short-circuits since metal never comes into contact with live components, and it simplifies the sensor attachment process even when terminals are covered since the sensor can be simply clipped around the cable without removing the cover.


Harmonic Testing | Analyze from the fundamental wave up to the 13th order with the PW3365 Clamp On Power Logger (from version 2.00)

Use the Hioki PW3365 Clamp On Power Logger to analyze the fundamental waveform up to the 13th order of harmonic components that are included in the voltage and current signals of 50/60Hz power lines. Display the total harmonic distortion (THD) and RMS and harmonic content of each harmonic order as a numerical list or graph. In particular, you can now safely and easily measure the 5th and 7th harmonic within the harmonic component which tend to have the greatest impact on power quality.


Graphical, easy-to-understand guidance on how to connect the clamp-on power logger

The PW3365’s Quick Setup feature guides you through the process of setting up the instrument for measurement, right up to starting measurement, to make even 3-phase power measurement a breeze. Since any mistaken connections will trigger a FAIL message, the feature also helps prevent measurement mistakes.


Display clamp-on power logger measurement results as a graph so you can review them at a glance

The PW3365 displays recorded measured values as a graph for convenient use in power management. In addition to instantaneous measured values, you can review maximum, minimum, and average values by moving the cursor on the demand and trend graph displays.


Get results from the job site in real-time, GENNECT CROSS SF4000

Capture data on the PC while testing remotely


Learn more

Basic specifications (Accuracy guaranteed for 1 year, Post-adjustment accuracy guaranteed for 6 months)

Measurement line & number of circuits50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels
Measurement itemsVoltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power, apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand
Voltage ranges400 V AC (Effective measurement range: 90.0 V to 520.0 V)
HarmonicHarmonic voltage, harmonic current, voltage total harmonic distortion (THD-F or THD-R), current total harmonic distortion (THD-F or TDH-R), up to 13th order
Current ranges500.00 mA to 5.0000 kA AC (depends on current sensor in use),
50.000 mA to 5.0000 A AC (Leak clamp on sensor only)
Power ranges200.00 W to 6.0000 MW (depends on voltage/current combination and measured line type)
Basic accuracyVoltage : ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020)
Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy
Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1)
Display update rate0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication)
Save destinationSD/SDHC Memory card, or internal memory at real time
Data save interval1 sec to 30 sec, 1 minute to 60 minutes, 14 selections
Save itemsMeasurement value save: Average only / Average, Maximum, Minimum value
Screen copy: BMP form (saved every 5 min. at minimum interval time)
Waveform save: Binary waveform data
InterfacesSD/SDHC memory card, LAN 100BASE-TX: HTTP server function, remote settings via communication program, data download, USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download
FunctionsConnection check, Quick Set navigation guide, clock
Power supplyAC adapter Z1008: (100 to 240 V AC, 50/60 Hz), 45 VA (including AC adapter)
Battery pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 5 hours of continuous use (with back light off)
Dimensions and mass180 mm (7.09 in)W × 100 mm (3.94 in)H × 48 mm (1.89 in)D, 540 g (19 oz) without PW9002
180 mm (7.09 in)W × 100 mm (3.94 in)H × 68 mm (2.68 in)D, 820 g (28.9 oz) with PW9002
AccessoriesSafety Voltage Sensor PW9020 ×1 set, AC adapter Z1008 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip (red, yellow, blue and white each 4), Spiral tubes in black (cord bundling for current sensors and voltage sensors) ×10

Log into your myHioki account to access more technical documents and information where available.

Seminar Videos On Demand

No results were found.

Catalogs

Catalog: CLAMP ON POWER LOGGER PW3365 Download PDF  [5MB] English
Catalog: GENNECT CROSS SF4000 Download PDF  [1MB] English

User Guides

No results were found.

Manuals

Communications Manual English
Ver.00
Instruction Manual German
Ver.01
Instruction Manual French
Ver.01
Measurement Guide French
Ver.01
Measurement Guide German
Ver.01
Measurement Guide English
Ver.01
Instruction Manual English
Ver.02
Measurement Guide Simplified Chinese
Ver.01
Instruction Manual Simplified Chinese
Ver.01

Outline Drawings


Ver.00

Ver.00

Ver.00

Drivers, Firmware

USB driver (for PW3360/PW3365)  Freeware Version 2.0.0.9 
PW3360/PW3365 Auto Excel Graph Creation Application  Freeware Version 2.03.0 
PW3360/PW3365 Settings and Download Application  Freeware Version 2.03.0 
GENNECT Cross for Windows  Freeware V2.11 
CLAMP ON POWER LOGGER PW3365  Firmware V2.00 

Others

No results were found.

Options

Current measurement

For power or load current measurement

(1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)

CLAMP ON SENSOR 9660

• 40Hz to 5kHz • 100 A AC rated input • φ 15 mm (0.59 in) core dia.

Learn more

CLAMP ON SENSOR 9661

• 40Hz to 5kHz • 500 A AC rated input • φ 46 mm (1.81 in) core dia.

Learn more

CLAMP ON SENSOR 9669

• 40Hz to 5kHz • 1000 A AC rated input • φ 55 mm (2.17 in) Core dia.

Learn more

CLAMP ON SENSOR 9694

• 40Hz to 5kHz • 5A AC rated input • φ 15 mm (0.59 in) core dia.

Learn more

CLAMP ON SENSOR 9695-02

• 40Hz to 5kHz • 50 A AC rated input • φ 15 mm (0.59 in) core dia.

Learn more

CLAMP ON SENSOR 9695-03

• 40Hz to 5kHz • 100 A AC rated input • φ 15 mm (0.59 in) core dia.

Learn more

AC FLEXIBLE CURRENT SENSOR CT9667

• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input

Learn more

CONNECTION CABLE 9219

Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length

Leak current

For leak current measurement (not capable of power measurement)

Caution: Up to 5 A on Model PW3365

CLAMP ON LEAK SENSOR 9657-10

• 40 Hz to 5 kHz • Rated 5 A AC • φ 40 mm (1.57 in) core dia.

Learn more

CLAMP ON LEAK SENSOR 9675

• 40 Hz to 5 kHz • Rated 5 A AC • φ 30 mm (1.18 in) core dia.

Learn more

Adapter

For clamp sensor

CLAMP ON ADAPTER 9290-10

• Primary 1000A, secondary 100A (1/10 ratio) output • Superior phase angle characteristics for power

Learn more

Voltage measurement

*PW9020 ×4 pieces are bundled, additional single sensors also available

◆SAFETY VOLTAGE SENSOR PW9020

For PW3365, 3 m (9.84 ft) length

Storage media

SD Card Precaution

Use only SD Cards sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.

SD MEMORY CARD 2GB Z4001

2 GB capacity

SD MEMORY CARD Z4003

8 GB capacity

Power supply

*Z1008 is bundled, Model 9459 is a replacement battery pack included with the Battery Set PW9002.

BATTERY PACK 9459

NiMH, Charges while installed in the main unit

BATTERY SET PW9002

Battery case and Battery Pack 9459 Set

AC ADAPTER Z1008

100 to 240V AC

Other options

Z5004 hang the cords on the metal surface. C1005 store Current sensor ×2, Voltage sensor ×3 pieces

CARRYING CASE C1005

For PW3360/3365 series, for storing options

CARRYING CASE C1008

For PW3365, for storing Current sensor ×3, Voltage sensor ×4 pieces

MAGNETIC STRAP Z5004

PC peripherals

GENNECT CROSS SF4000

• Software automatically recognizes LAN-connected measuring instrument • Display acquired data as graphs in real-time • Windows compatible

Learn more

LAN CABLE 9642

Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length

POWER LOGGER VIEWER SF1001

• Easy graphical processing of measurement data saved with the PW3360/3365 series, 3169 series on a PC

Learn more

Applications

Gallery

No results were found.


  • Search


    Search Results Include Discontinued Products

    Login to myHIOKI

    Download

  • Ask

    • Ask Online

     

  • Quote

    • Request a Quote
    • Locate a Distributor

Related Products List