CLAMP ON POWER LOGGER
PW3365
Eliminate the Risk of Short-Circuits and Electrical Accidents
Hioki Clamp On Power Meters are multi-channel power measuring devices utilizing clamp sensor input to accurately and safely measure power on single-phase to three-phase lines. The PW3365 power logger takes safety and convenience one step further by being the world’s first non-metallic contact power meter that utilizes completely covered voltage clips that can be attached to any part of a cable or busbar. Customers can now monitor power demand and other power parameters to aid in energy audits and validate energy saving measures without risk of short-circuit accidents, power interruptions, or bodily injury due to electrocutions. Key Features • Voltage measurement from the top of the cable, zero risk of short circuit • Supports single to three-phase, 4-wire circuits • Measure between 90V to 520V • Slim, compact design that can be placed anywhere • Store months of data on SD cards • The QUICK SET function guides you in making the right connections • WHM (watt-hour meter) connection checking function installed
| PW3365-20 | English model, main unit only |
|---|
Note: Clamp On Power Logger PW3365 by itself does not support current and power measurements. Current and power measurements require clamp on sensors, sold separately. Use only HIOKI SD cards guaranteed to work for saving measurement data (options, sold separately).
Although technicians had to connect instruments to metal terminals in order to measure voltage when measuring power in the past, Hioki’s newly developed no-metal-contact voltage sensor makes it possible to measure voltage simply by clamping the sensor around an insulated wire. This approach completely eliminates the risk of short-circuits since metal never comes into contact with live components, and it simplifies the sensor attachment process even when terminals are covered since the sensor can be simply clipped around the cable without removing the cover.
Use the Hioki PW3365 Clamp On Power Logger to analyze the fundamental waveform up to the 13th order of harmonic components that are included in the voltage and current signals of 50/60Hz power lines. Display the total harmonic distortion (THD) and RMS and harmonic content of each harmonic order as a numerical list or graph. In particular, you can now safely and easily measure the 5th and 7th harmonic within the harmonic component which tend to have the greatest impact on power quality.
The PW3365’s Quick Setup feature guides you through the process of setting up the instrument for measurement, right up to starting measurement, to make even 3-phase power measurement a breeze. Since any mistaken connections will trigger a FAIL message, the feature also helps prevent measurement mistakes.
The PW3365 displays recorded measured values as a graph for convenient use in power management. In addition to instantaneous measured values, you can review maximum, minimum, and average values by moving the cursor on the demand and trend graph displays.
Capture data on the PC while testing remotely
| Measurement line & number of circuits | 50/60 Hz, Single phase 2 wires (1/2/3 circuits), Single phase 3 wires (1 circuit), Three phases 3 wires (1 circuit), Three phases 4 wires (1 circuit), Current only: 1 to 3 channels |
|---|---|
| Measurement items | Voltage RMS, current RMS, voltage fundamental wave value, current fundamental wave value, voltage fundamental wave phase angle, current fundamental wave phase angle, frequency (U1), voltage waveform peak (absolute value), current waveform peak (absolute value), active power, reactive power, apparent power, power factor (with lag/lead display) or displacement power factor (with lag/lead display), active energy (consumption, regeneration), reactive energy (lag, lead), energy cost display, active power demand quantity (consumption, regeneration), reactive power demand quantity (lag, lead), active power demand value (consumption, regeneration), reactive power demand value (lag, lead), power factor demand |
| Voltage ranges | 400 V AC (Effective measurement range: 90.0 V to 520.0 V) |
| Harmonic | Harmonic voltage, harmonic current, voltage total harmonic distortion (THD-F or THD-R), current total harmonic distortion (THD-F or TDH-R), up to 13th order |
| Current ranges | 500.00 mA to 5.0000 kA AC (depends on current sensor in use), 50.000 mA to 5.0000 A AC (Leak clamp on sensor only) |
| Power ranges | 200.00 W to 6.0000 MW (depends on voltage/current combination and measured line type) |
| Basic accuracy | Voltage : ±1.5% rdg. ±0.2% f.s(combined accuracy with PW3365-20 + PW9020) Current : ±0.3% rdg. ±0.1% f.s. + clamp sensor accuracy Active power : ±2.0% rdg. ±0.3% f.s. + clamp sensor accuracy (at power factor = 1) |
| Display update rate | 0.5 sec (except when accessing SD card or internal memory, or during LAN/USB communication) |
| Save destination | SD/SDHC Memory card, or internal memory at real time |
| Data save interval | 1 sec to 30 sec, 1 minute to 60 minutes, 14 selections |
| Save items | Measurement value save: Average only / Average, Maximum, Minimum value Screen copy: BMP form (saved every 5 min. at minimum interval time) Waveform save: Binary waveform data |
| Interfaces | SD/SDHC memory card, LAN 100BASE-TX: HTTP server function, remote settings via communication program, data download, USB 2.0: When connected to a PC, the SD Card and internal memory are recognized as removable storage devices, remote settings via communication program, data download |
| Functions | Connection check, Quick Set navigation guide, clock |
| Power supply | AC adapter Z1008: (100 to 240 V AC, 50/60 Hz), 45 VA (including AC adapter) Battery pack 9459: (DC 7.2 V, 3 VA, charging time 6 hr 10 m), 5 hours of continuous use (with back light off) |
| Dimensions and mass | 180 mm (7.09 in)W × 100 mm (3.94 in)H × 48 mm (1.89 in)D, 540 g (19 oz) without PW9002 180 mm (7.09 in)W × 100 mm (3.94 in)H × 68 mm (2.68 in)D, 820 g (28.9 oz) with PW9002 |
| Accessories | Safety Voltage Sensor PW9020 ×1 set, AC adapter Z1008 ×1, USB cable ×1, Instruction manual ×1, Measurement guide ×1, Color clip (red, yellow, blue and white each 4), Spiral tubes in black (cord bundling for current sensors and voltage sensors) ×10 |
Log into your myHioki account to access more technical documents and information where available.
| No results were found. |
|
|
Nov 6, 2019 - Nov 8, 2019 | |
|
|
Sep 18, 2019 - Sep 20, 2019 | |
|
|
May 29, 2019 - May 31, 2019 | |
|
|
May 21, 2019 - May 23, 2019 |
| Catalog: CLAMP ON POWER LOGGER PW3365 | Download PDF [8MB] |
English |
| Catalog: GENNECT CROSS SF4000 | Download PDF [1MB] |
English |
| No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
| Communications Manual |
English |
Ver.00 | |
| Measurement Guide |
French |
Ver.01 | |
| Measurement Guide |
German |
Ver.01 | |
| Measurement Guide |
English |
Ver.01 | |
| Measurement Guide |
Simplified Chinese |
Ver.01 | |
|
CLAMP ON POWER LOGGER PW3365-20 [37MB] |
Instruction Manual |
French |
Ver.02 |
|
CLAMP ON POWER LOGGER PW3365-20 [39MB] |
Instruction Manual |
German |
Ver.02 |
|
CLAMP ON POWER LOGGER PW3365-20,PW3365-30 [8MB] |
Instruction Manual |
English |
Ver.03 |
|
CLAMP ON POWER LOGGER PW3365-30 [9MB] |
Instruction Manual |
Simplified Chinese |
Ver.02 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
|
CLAMP ON POWER LOGGER PW3365-20 [78KB] |
Ver.00 |
|
CLAMP ON POWER LOGGER PW3365-30 [78KB] |
Ver.00 |
|
CLAMP ON POWER LOGGER PW3365-10,PW3365-20,PW3365-30 (With Battery Set PW9002) [88KB] |
Ver.00 |
|
CLAMP ON POWER LOGGER PW3365-10,PW3365-20,PW3365-30 [101KB] |
Ver.02 |
| USB driver (for PW3360/PW3365) | Freeware | Version 2.0.0.9 |
| PW3360/PW3365 Auto Excel Graph Creation Application | Freeware | Version 2.03.0 |
| PW3360/PW3365 Settings and Download Application | Freeware | Version 2.03.0 |
| GENNECT Cross for Windows | Freeware | V2.11 |
| CLAMP ON POWER LOGGER PW3365 | Firmware | V2.00 |
| No results were found. |
For power or load current measurement
(1 sensor necessary for single-phase measurements, and 2 or 3 sensors required for 3-phase measurements)
CLAMP ON SENSOR 9669
• 40Hz to 5kHz • 1000 A AC rated input • φ 55 mm (2.17 in) Core dia.
CLAMP ON SENSOR 9695-02
• 40Hz to 5kHz • 50 A AC rated input • φ 15 mm (0.59 in) core dia.
CLAMP ON SENSOR 9695-03
• 40Hz to 5kHz • 100 A AC rated input • φ 15 mm (0.59 in) core dia.
AC FLEXIBLE CURRENT SENSOR CT9667
• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input
CONNECTION CABLE 9219
Connect with the 9695-02/ -03, Output BNC terminal, 3m (9.84ft) length
For leak current measurement (not capable of power measurement)
Caution: Up to 5 A on Model PW3365
CLAMP ON LEAK SENSOR 9657-10
• 40 Hz to 5 kHz • Rated 5 A AC • φ 40 mm (1.57 in) core dia.
For clamp sensor
CLAMP ON ADAPTER 9290-10
• Primary 1000A, secondary 100A (1/10 ratio) output • Superior phase angle characteristics for power
*PW9020 ×4 pieces are bundled, additional single sensors also available
◆SAFETY VOLTAGE SENSOR PW9020
For PW3365, 3 m (9.84 ft) length
SD Card Precaution
Use only SD Cards sold by HIOKI. Compatibility and performance are not guaranteed for SD cards made by other manufacturers. You may be unable to read from or save data to such cards.
SD MEMORY CARD 2GB Z4001
2 GB capacity
SD MEMORY CARD Z4003
8 GB capacity
*Z1008 is bundled, Model 9459 is a replacement battery pack included with the Battery Set PW9002.
BATTERY PACK 9459
NiMH, Charges while installed in the main unit
BATTERY SET PW9002
Battery case and Battery Pack 9459 Set
AC ADAPTER Z1008
100 to 240V AC
Z5004 hang the cords on the metal surface. C1005 store Current sensor ×2, Voltage sensor ×3 pieces
CARRYING CASE C1005
For PW3360/3365 series, for storing options
CARRYING CASE C1008
For PW3365, for storing Current sensor ×3, Voltage sensor ×4 pieces
MAGNETIC STRAP Z5004
GENNECT CROSS SF4000
• Software automatically recognizes LAN-connected measuring instrument • Display acquired data as graphs in real-time • Windows compatible
LAN CABLE 9642
Straight Ethernet cable, supplied with straight to cross conversion adapter, 5 m (16.41 ft) length
POWER LOGGER VIEWER SF1001
• Easy graphical processing of measurement data saved with the PW3360/3365 series, 3169 series on a PC
No results were found.