DIGITAL MULTIMETER
DT4256
Standard DMM that Delivers Top Safety and Reliability - General Purpose Testers with Rich Measurement Functions
The Hioki DT4200 Digital Multimeter Series consist of a complete lineup of 9 models ranging from professional to industrial to pocket meters, delivering a super fast response rate and safety features that take electrical testing to a higher level. The DT4256 is a digital multimeter designed to deliver maximum functionality for use in a wide range of settings. CAT IV 600 V, CAT III 1000 V Key Features • ±0.3% DC V basic accuracy, wide 40 Hz to 1 kHz AC V frequency characteristics • Measure up to 10A with direct input • Dual display lets you check voltage and frequency simultaneously • Low-pass filter cuts high harmonics (when measuring inverter fundamental waveforms) • USB communications function supports PC measurements (optional) • Broad -25 (-13°F) to 65°C (149°F) operating temperature range (DT4256)
| DT4256 | Multi-functional model, with 10 A direct input |
|---|
If you connect the DT4256 to a computer with the optional Communication Package DT4900-01, you can graph data stored in the instrument’s internal memory and display measurement results in real time on the computer. In addition, displayed measured values can be saved (in text format). *The computer and multimeter are electrically isolated by means of optical communications so that data can be sent without concern for electrical hazards.
Digital multimeters implement two types of measurement: mean-value measurement and true RMS measurement. The two methods yield significantly different measurement results for current waveforms, which are often distorted. For accurate measurement, it is necessary to use an instrument with true RMS capability.
All development, design, and manufacturing processes for almost all Hioki digital multimeters are carried out at our Head Office in Nagano Prefecture. Some of the industry’s most advanced technological capabilities enable us to deliver products of the highest possible quality.
To ensure operators’ ability to use measuring instruments safely, IEC 61010 classifies the locations in which instruments are used into a series of safety-based measurement categories (ranging from CAT II to CAT IV). Using an instrument that does not satisfy the required safety level can lead to an electrical accident.
| DC Voltage range | 600.0 mV to 1000 V, 5 ranges Basic accuracy: ±0.3 % rdg. ±3 dgt. |
|---|---|
| AC Voltage range | 6.000 V to 1000 V, 4 ranges, Frequency characteristics: 40 Hz to 1 kHz Basic accuracy 40 - 500 Hz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
| AUTO AC/DCV | Yes |
| Resistance range | 600.0 Ω to 60.00 MΩ, 6 ranges, Basic accuracy: ±0.7 % rdg. ±3 dgt. |
| DC Current range | 60.00 mA to 10.00 A, 4 ranges, Basic accuracy: ±0.9 % rdg. ±3 dgt. |
| AC Current range | 600.0 mA to 10.00 A, 3 ranges, Basic accuracy 40 - 500 Hz : ±1.4 % rdg. ±3 dgt. (True RMS, crest factor 3, 40 Hz to 1 kHz) |
| AC Current range (use with Clamp on probes) | 10.00 A to 1000 A, 7 ranges, Add the Clamp on probe accuracy to basic accuracy 40 - 1 kHz : ±0.9 % rdg. ±3 dgt. (True RMS, crest factor 3) |
| Voltage detection (50/60 Hz) | Hi: AC40 V to 600 V, Lo: AC80 V to 600 V |
| Capacitance range | 1.000 μF to 10.00 mF, 5 ranges, Basic accuracy: ±1.9 % rdg. ±5 dgt. |
| Frequency range | 99.99 Hz (5 Hz or more) to 99.99 kHz, 4 ranges (limited by the minimum detectable voltage and current), Basic accuracy: ±0.1 % rdg. ±1 dgt. |
| Continuity check | Continuity threshold [ON]: 25 Ω or less (Indicate buzzer sound, red LED), [OFF]: 245 Ω or more, Response time: 0.5 ms or more |
| Diode test | Open terminal voltage: 5.0 V or less, Testing current 0.5 mA or less, Threshold of forward voltage: 0.15 V to 1.5 V |
| Other functions | Filter function, Display value hold, Auto hold, Max/Min/Average value display, Relative display, Auto-power save, USB communication (option) |
| Display | Main and Sub displays: 4-digits LCD, max. 6000 digits, bar graph |
| Display refresh rates | 5 times/s (Capacitance measurement: 0.05 to 5 times/s, depending on measured value, Frequency: 1 to 2 time/s, Temperature: 1 time/s ) |
| Power supply | LR03 alkaline batteries ×4, Continuous use: 130 hours (backlight OFF) |
| Dimensions and mass | 84 mm (3.31 in)W × 174 mm (6.85 in)H× 52 mm (2.05 in)D, 390 g (13.8 oz) (including batteries and holster) |
| Accessories | Test lead L9207-10 ×1, Holster ×1, Instruction manual ×1, LR03 alkaline battery ×4 |
Log into your myHioki account to access more technical documents and information where available.
| No results were found. |
|
|
Nov 6, 2019 - Nov 8, 2019 | |
|
|
Sep 18, 2019 - Sep 20, 2019 | |
|
|
May 29, 2019 - May 31, 2019 |
| Catalog: COMMUNICATION PACKAGE (USB) DT4900-01 | Download PDF [1MB] |
English |
| Catalog: DIGITAL MULTIMETER DT4200 Series | Download PDF [5MB] |
English |
| No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
| Instruction Manual |
English |
Ver.02 | |
| Instruction Manual |
French |
Ver.00 | |
| Instruction Manual |
German |
Ver.00 | |
| Instruction Manual |
Simplified Chinese |
Ver.02 | |
| Instruction Manual |
Korean |
Ver.02 | |
| Instruction Manual |
Spanish |
Ver.02 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
|
DIGITAL MULTIMETER DT4256,DT4256-20 [125KB] |
Ver.01 |
|
DIGITAL MULTIMETER DT4252,DT4253,DT4254,DT4255,DT4256 [100KB] |
Ver.05 |
| DMM Communicator for DT4200s | Freeware | Version 2.10 |
| Flyer: Usable temperature range Max.65°C Max.-25°C | Download PDF [1MB] |
English |
Options for the L9207-10 (L9207-10 is a bundled accessory)
CONTACT PIN SET L4933
Attaches to the tip of the Test Lead L9207-10/DT4911, L9206, 60V DC/ 30V AC
SMALL ALLIGATOR CLIP SET L4934
Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V
TEST LEAD L9207-10
90 cm (2.95 ft) length
Clamp on current sensors for the DT4281, DT4253/4255/4256
CLAMP ON PROBE 9010-50
• Use for level measurement • 40 Hz to 1 kHz • 10 to 500 A AC • φ 46 mm (1.81 in) core dia.
CLAMP ON PROBE 9018-50
• Excellent phase characteristics • 40 Hz to 3 kHz • 10 to 500A AC • φ 46 mm (1.81 in) core dia.
CLAMP ON PROBE 9132-50
• Use for level measurement • 40 Hz to 1 kHz • 20 to 1000A AC • φ 55 mm (2.17 in) core dia.
CONVERSION ADAPTER 9704
Receiving end: Female BNC; Output end: Male banana-plug *Not compatible with older generation Memory Hicorders with banana input terminals
Options for the L4930
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
CONNECTION CABLE SET L4930
1.2 m (3.94 ft) length
EXTENSION CABLE SET L4931
Expands the length of the cable with banana plug, 1.5 m (4.92 ft) length
TEST PIN SET L4932
Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
SMALL ALLIGATOR CLIP SET L4934
Attaches to the tip of the L4932, L9207-10/DT4911, L9206, CAT III 300V, CAT II 600V
ALLIGATOR CLIP SET L4935
Attaches to the tip of the banana plug cable, CAT IV 600V, CAT III 1000V
BUS BAR CLIP SET L4936
Attaches to the tip of the banana plug cable, CAT III 600V
MAGNETIC ADAPTER SET L4937
Attaches to the tip of the banana plug cable, CAT III 1000V
TEST PIN SET L4938
Attaches to the tip of the banana plug cable, CAT III 600V
BREAKER PIN SET L4939
Attaches to the tip of the banana plug cable, CAT III 600V
COMMUNICATION PACKAGE (USB) DT4900-01
For DT4280s/4250s, compatible to Windows 8.1/ 8/ 7/ Vista
CARRYING CASE C0202
MAGNETIC STRAP Z5020
Extra strength
No results were found.