Capture High- to Low-Voltage Signals in a Single Device! Rugged, Professional and Ready for the Field
Hioki Memory HiCorders are high-speed waveform monitoring and recording devices that can simultaneously measure multiple quick-changing phenomena due to complete isolation between channels and from each channel to the ground. The MR8880 is a data acquisition (DAQ) recorder built in with 4 analog channels that can accept direct input of 600V, enabling measurements of 3-phase systems. Key Features • CAT III 600V isolation performance; directly measure a 480V power line • 4 completely isolated channels let you simultaneously record data on a 3-phase power line plus have one extra channel • Tough against harsh environments; -10°C to 50°C operating temperature range • Built to withstand mechanical shocks and vibrations (ships standard with side protectors) • Make settings easily with PRESETS function
MR8880-20 | 4ch, printer unit option, English model |
---|
Note: Input cords and Battery Pack are not included. Purchase the cords appropriate for your application separately. Printer Unit MR9000 is optional and sold separately.
Watch this video to learn how to use the Hioki MR8880’s trigger function to definitively record the startup current when a motor is powered on. Pre-trigger settings let you capture details about the situation before and after the trigger is activated, and numerical data of the peak current waveform can be easily identified using the built-in cursor functions.
Watch this video to learn how to use logic probes to analyze the timing of control signals via the 8 logic and 4 analog channels built-in to the Hioki MR8880. Based on the AND / OR settings, the MR8880’s trigger will activate with respect to the specified logic level. Pre-trigger settings let you capture details about the situation before and after the trigger is activated.
Watch this video to learn how to easily detect when a voltage drop on the commercial power supply will occur by using the trigger function on a Hioki Memory HiCorder and setting the peak waveform level as the voltage level. The waveforms can also be automatically printed onsite and saved to portable external media for later analysis on a PC.
Number of channels | 4 analog channels + 8 logic channels (standard) Note: Isolated analog channels, isolated input and frame, logic has common GND |
---|---|
Measurement ranges (10 div full-scale) | 4 channels of voltage measurement; mode switchable between instantaneous waveform or RMS value, 10 mV to 100 V/div, 13 ranges, resolution: 1/640 of range RMS value mode: 30 Hz to 10 kHz, Crest factor: 2 |
Max. rated voltage | Between terminals: 600 V AC/DC, Between terminal to earth: 600 V AC/DC CAT III; 300 V AC/DC CAT IV |
Frequency characteristics | DC to 100 kHz (±3dB) |
Time axis (High-speed function) | 100 µs to 100 ms/div, 10 ranges, Sampling period: 1/100 of range |
Recording intervals (Real-time function) | 100 µs to 1 minute, 19 selections (simultaneous sampling in all channels) |
Measurement functions | High-speed function (high speed recording) Real-time function (actual time recording) |
Memory capacity | 14-bits × 1M-words/ch (1 word = 2 bytes) |
Removable storage | CF card slot ×1 (Up to 2 GB), USB 2.0 memory ×1 |
Printing | [Printer unit is option] 112 mm (4.41 in) × 18 m (59.06 ft), thermal paper roll, Recording speed : 10 mm (0.39 in)/sec Note: Printing is not supported when using alkaline batteries |
Display | 5.7-inch VGA-TFT color LCD (640 × 480 dots) |
Displayable languages | English, Japanese, Chinese |
Communication interfaces | USB 2.0 mini-B receptacle × 1; Transfers files from the installed CF card or USB memory stick to a PC when connected, and External PC control |
Power supply | AC adapter Z1002: 100 to 240 V AC (50/60 Hz), 45 VA (include AC adapter, when Real-time recording), 107 VA (include AC adapter, when Real-time recording and printing) Battery pack Z1000: AC adapter has priority when used in combination with battery pack, recharge with AC adapter 3 hours, Continuous use 3 hours (with back-light ON) LR6 (AA) alkaline batteries ×8, Continuous use 40 minutes, (with back-light ON, cannot be used with the Printer unit) DC power supply: 10 to 28 V DC (cable available by special order) |
Dimensions and mass | 205 mm (8.07 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D, 1.66 kg (58.6 oz) (with the Battery pack installed) When printer is combined - with main unit: 303 mm (11.93 in)W × 199 mm (7.83 in)H × 67 mm (2.64 in)D, 2.16 kg (76.2 oz) (with the Battery pack installed) |
Accessories | Instruction manual ×1, AC adapter Z1002 ×1, Alkaline battery box ×1, Strap ×1, USB cable ×1, Application disk (Wave viewer Wv, Communication commands table) ×1 |
Compatible models | LabVIEW | MATLAB script |
---|---|---|
MR8880-20 | N/A | N/A |
Log into your myHioki account to access more technical documents and information where available.
No results were found. |
![]() |
Jan 27, 2019 - Jan 31, 2019 |
Catalog: MEMORY HiCORDER MR8880 | Download PDF [4MB] |
English |
No results were found. |
If you can not download, log into your myHioki account to access more technical documents and information where available.
MEMORY HiCORDER MR8880-20 [301KB] |
Measurement Guide |
English |
Ver.00 |
MEMORY HiCORDER MR8880-20 [6MB] |
Instruction Manual |
French |
Ver.01 |
MEMORY HiCORDER MR8880-20 [6MB] |
Instruction Manual |
German |
Ver.01 |
MEMORY HiCORDER MR8880-20 [6MB] |
Instruction Manual |
Spanish |
Ver.01 |
MEMORY HiCORDER MR8880-20 [17MB] |
Instruction Manual |
English |
Ver.07 |
MEMORY HiCORDER MR8880-21 [17MB] |
Instruction Manual |
Simplified Chinese |
Ver.04 |
If you can not download, log into your myHioki account to access more technical documents and information where available.
MEMORY HiCORDER MR8880 [682KB] |
Ver.00 |
MEMORY HiCORDER MR8880 (With Printer Unit MR9000) [645KB] |
Ver.00 |
MEMORY HiCORDER MR8880-20 [665KB] |
Ver.00 |
MEMORY HiCORDER MR8880-20 (With Printer Unit MR9000) [635KB] |
Ver.00 |
MEMORY HiCORDER MR8880-21 [680KB] |
Ver.00 |
MEMORY HiCORDER MR8880-21 (With Printer Unit MR9000) [637KB] |
Ver.00 |
No results were found. |
MEMORY HiCORDER MR8880-20 [100KB] |
Ver.08 |
MEMORY HiCORDER MR8880-20 | Firmware | V1.10 |
MEMORY HiCORDER & MEMORY HiLOGGER Application Disk | Freeware | Rev 41 |
No results were found. |
RECORDING PAPER 9234
A6 width 112 mm (4.41 in) × 18 m (59.06 ft), 10 rolls/set
PRINTER UNIT MR9000
Printing width 100 mm (3.94 in), used together with the MR8880 main body, includes 1 roll of recording paper
Includes a PC card adapter with the 9728/9729, and the 9830
Use only CF Cards or USB drive sold by HIOKI. Compatibility and performance are not guaranteed for CF cards/USB memory stick made by other manufacturers. You may be unable to read from or save data to such cards.
USB DRIVE Z4006
16 GB, Long-life, High-reliability SLC Flash Memory
*Voltage is limited to the specifications of the input section
GRABBER CLIP 9790-02
Red/black set attaches to the ends of the Connection Cord L9790
CONTACT PIN 9790-03
Red/black set attaches to the ends of the Connection Cord L9790
CONNECTION CORD L9790
• Flexible φ 4.1 mm (0.16 in) thin dia. • Cable allowing for up to 600 V input • 1.8 m (5.91 ft) length
ALLIGATOR CLIP L9790-01
Red/black set attaches to the ends of the Connection Cord L9790
*Voltage is limited to the specifications of the input section
GRABBER CLIP 9243
Attaches to the tip of the banana plug cable, Red/ Black: 1 each, 196 mm (7.72 in) length, CAT III 1000 V
CONNECTION CORD L9197
•φ 5.0 mm (0.20 in) dia •Cable allows for up to 600 V input •1.8 m (5.91 ft) length •Includes detachable large alligator clips
CONNECTION CORD L9198
•φ 5.0 mm (0.20 in) dia. •Cable allows for up to 300 V input •1.7 m (5.58 ft) length •Small alligator clip
*Voltage to ground is within this product's specifications. Separate power source is also required.
DIFFERENTIAL PROBE P9000
• Waveform only for exclusive use with Memory HiCorders (P9000-01) or waveform/RMS value switchable (P9000-02) • For use with input of up to 1 kV AC/DC • Requires separate power supply
AC ADAPTER Z1008
100 to 240V AC
*For P9000. Inquire with your Hioki distributor.
(1) Bus powered USB cable
(2) USB(A)- Micro B cable
(3) 3-prong cable
*Voltage to ground is within this product's specifications. Separate power source is also required.
DIFFERENTIAL PROBE 9322
• For up to 2 kV DC or 1 kV AC • Use with AC Adapter 9418-15 • Frequency band width up to 10MHz
AC ADAPTER 9418-15
100 to 240V AC
NON-CONTACT AC VOLTAGE PROBE SP3000
Sold individually
NON-CONTACT AC VOLTAGE PROBE SP3000
• Supports φ1mm to 2.5mm covered wires • 10Hz to 100kHz frequency bandwidth • 5Vrms 14Vp-p rated measurement voltage
AC VOLTAGE PROBE SP9001
Sold individually
* Only the small terminal types can be used.
* The 9323 is not required for the small-terminal types 9327, 9320-01, 9321-01 and MR9321-01.
LOGIC PROBE 9320-01
• 4 channels for contact voltage signals • 500ns response • Miniature terminal type
CONVERSION CABLE 9323
• Used for connecting the 9320/9321/MR9321 and the 9324 to the Memory HiCorder with small logic terminal models
LOGIC PROBE MR9321-01
• 4 isolated channels • ON/OFF detection of AC/DC voltage • Large terminal type
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x. *The separately available Conversion Cable CT9900 is required in order to use a sensor with PL23 (10-pin) terminal.
CLAMP ON SENSOR 9272-05
• 1Hz to 100kHz (Phase: 5Hz to 50kHz) • Rated 20A/200A AC/DC • φ 46 mm (1.81 in) core dia.
AC/DC CURRENT PROBE CT6841-05
• DC to 1MHz (Phase: up to 300kHz) • Rated 20A AC/DC • φ 20 mm (0.79 in) core dia.
AC/DC CURRENT PROBE CT6843-05
• DC to 500kHz (Phase: up to 300kHz) • Rated 200A AC/DC • φ 20 mm (0.79 in) core dia.
AC/DC CURRENT SENSOR CT6862-05
• DC to 1MHz (Phase: up to 300kHz) • Rated 50A AC/DC • φ 24 mm (0.94 in) core dia.
AC/DC CURRENT SENSOR CT6863-05
• DC to 500kHz (Phase: up to 300kHz) • Rated 200A AC/DC • φ 24 mm (0.94 in) core dia.
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x. *The separately available Conversion Cable CT9900 is required in order to use a sensor with PL23 (10-pin) terminal.
AC/DC CURRENT SENSOR 9709-05
• DC to 100kHz (Phase: up to 100kHz) • Rated 500A AC/DC • φ 36 mm (1.42 in) core dia.
AC/DC CURRENT PROBE CT6844-05
• DC to 200kHz (Phase: up to 200kHz) • Rated 500A AC/DC • φ 20 mm (0.79 in) core dia.
AC/DC CURRENT PROBE CT6845-05
• DC to 100kHz (Phase: up to 100kHz) • Rated 500A AC/DC • φ 50 mm (1.79 in) core dia.
AC/DC CURRENT PROBE CT6846-05
• DC to 20kHz (Phase: up to 20kHz) • Rated 1000A AC/DC • φ 50 mm (1.79 in) core dia.
AC/DC CURRENT SENSOR CT6875
• DC to 2MHz (Phase: up to 1MHz) • Rated 500A AC/DC • φ 36 mm (1.42 in) core dia.
CONVERSION CABLE CT9900
Convert PL23 (10-pin) terminal to ME15W (12-pin) terminal
*A separate power supply (CT955x) is required in order to use a high-precision current sensor.
*Only sensors with ME15W (12-pin) terminals (-05 type) can be connected to the CT955x. *The separately available Conversion Cable CT9900 is required in order to use a sensor with PL23 (10-pin) terminal.
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
SENSOR UNIT CT9555
• Power supply for current sensors when used alone • 1ch, with Waveform output
SENSOR UNIT CT9556
• Power supply for current sensors when used alone • 1ch, with Waveform/RMS output
SENSOR UNIT CT9557
• Power supply for current sensors when used alone • 4ch, with Waveform/Total Waveform/Total RMS output
AC/DC CURRENT SENSOR CT7631
・ DC to 10kHz (-3dB) ・Rated 100 A AC/DC ・φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7636
・ DC to 10kHz (-3dB) ・Rated 600 A AC/DC ・φ 33 mm (1.30 in) core dia.
AC/DC CURRENT SENSOR CT7642
・ DC to 10kHz (-3dB) ・Rated 2000 A AC/DC ・φ 55 mm (2.17 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7731
・ DC to 5 kHz (-3dB) ・ Rated 100 A AC/DC ・φ 33 mm (1.30 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7736
・ DC to 5 kHz (-3dB) ・ Rated 600 A AC/DC ・φ 33 mm (1.30 in) core dia.
AC/DC AUTO-ZERO CURRENT SENSOR CT7742
・ DC to 5 kHz (-3dB) ・ Rated 2000 A AC/DC ・φ 55 mm (2.17 in) core dia.
DISPLAY UNIT CM7290
• Use with CT7000 series • DCA, ACA, (DC+AC)A, frequency • WAVE, RMS, PEAK, Hz output
DISPLAY UNIT CM7291
• Built in Bluetooth(R) wireless technology • Use with CT7000 series • DCA, ACA, (DC+AC)A, frequency • WAVE, RMS, PEAK, Hz output
OUTPUT CORD L9095
Connect to BNC terminal, 1.5 m (4.92 ft) length
*For commercial power lines, 50/60 Hz
CLAMP ON PROBE 9018-50
• Excellent phase characteristics • 40 Hz to 3 kHz • 10 to 500A AC • φ 46 mm (1.81 in) core dia.
CLAMP ON PROBE 9132-50
• Use for level measurement • 40 Hz to 1 kHz • 20 to 1000A AC • φ 55 mm (2.17 in) core dia.
AC FLEXIBLE CURRENT SENSOR CT9667
• 10 Hz to 20 kHz (±3dB) • 5000 A/ 500 A AC rated input
*For commercial power lines, 50/60 Hz
CONVERSION ADAPTER 9199
Receiving side banana, output BNC terminal
AC ADAPTER 9445-02
For USA, 100 to 240 V AC, 9 V/ 1 A
CLAMP ON LEAK HiTESTER 3283
• True RMS • AC leak current and load current testing • 10 mA leak current range with 10 µA resolution • Load current up to 200 A
AC ADAPTER 9445-03
For EU, 100 to 240 V AC, 9 V/ 1 A
OUTPUT CORD L9094
3.5 mm (0.14 in) dia. mini plug to banana, 1.5 m (4.92 ft) length
OUTPUT CORD L9095
Connect to BNC terminal, 1.5 m (4.92 ft) length
*Clamp sensor sold separately
WAVE PROCESSOR 9335
• For the Memory HiCorder • Convert data, print and display waveforms
*Z1002 is a bundled accessory
BATTERY PACK Z1000
NiMH, Charges while installed in the main unit
AC ADAPTER Z1002
For main unit, 100 to 240 V AC
CARRYING CASE C1003
Includes compartment for options, soft case type
CONNECTION CORD L9217
Cord has insulated BNC connectors at both ends, 1.6 m (5.25 ft) length
No results were found.