| Safety Standards Measuring Instrument (Leakage Current of Medical Appliances) |
LEAK CURRENT HiTESTER ST5541 |
|
 |
|
 |
 |
|
|
 |
 |
| Leak current measurement, an essential part of electrical safety (For Standard- and Regulation-compliant) |
 |
- LEAK CURRENT HiTESTER ST5541: A low-cost solution that complies with standards governing general-use electrical devices
- Uninterrupted polarity switching function dramatically reduces cycle time.
- Support for rated currents up to 20 A gives the instrument more than adequate capability for testing products designed to comply with new standards.
- Touch panel features simple, interactive operation.
- Communications functionality and external I/O support allow automatic testing on production lines.
|
 |
| Note: For applications involving leak current measurement of medical-use electrical devices, use the ST5540. |
 |
| Basic specifications (Accuracy guaranteed for 1 year) |
 |
| Measurement methods |
Measurement of voltage drop across body simulated resistance points
Calculation and display of current values True rms measurement
Measurement unit floats relative to instrument ground. |
| Measurement modes |
Leak current measurement, voltage measurement, safety conductor current measurement |
| Standard compliance |
Electrical Appliances and Materials Safety Act
Measurement of touch current and protective conductor current: IEC 60990 (1999)
Electrical equipment for measurement, control, and laboratory use: IEC 61010-1 (2001)
Information technology equipment: IEC 60950-1 (2005)
Household and similar appliances: IEC 60335-1 (2001) + A1:2004 + A2:2006
Audio, video and similar electronic apparatus: IEC 60065 (2001) + A1:2005
Personnel Protection Systems for EV: UL-2231-1 (2002), UL-2231-2 (2002)
UL: UL-1492 (1996)
Electrical equipment for measurement, control, and laboratory use; current measurement circuits in damp conditions: IEC 61010-1 (2001) |
| Leak current measurement |
Ground leak current, 3 types of contact current, free current measurement, 3 types of enclosure leak current |
| Measurement current |
DC, AC (true rms, 15 Hz to 1 MHz), AC+DC (true rms, 15 Hz to 1 MHz), AC peak (15 Hz to 1 MHz) |
| Measurement ranges |
DC / AC / AC+DC mode:50 μA/500 μA/5 mA/50 mA
AC peak mode:500 μA/1 mA/10 mA/75 mA |
Measurement accuracy (current measurement) |
DC measurement: ±2.0% rdg. ±6 dgt. (typ.)
AC / AC+DC measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 100 kHz, typ.)
AC peak measurement: ±2.0% rdg. ±6 dgt. (15 Hz to 10 kHz, typ.) |
| Interfaces |
External I/O, USB 1.1 (communications), RS-232C |
| Functionality |
Automatic test, data storage for 100 target devices, clock, data backup, printed output (optional), etc. |
| HiTESTER power supply |
100/120/220/240 V AC (specify at time of order), 50/60 Hz, 30 VA rated power |
| Target device power supply input |
100 to 240 V AC, 50/60 Hz Rated current input from terminal block: 20 A |
| Target device power supply output |
Output from terminal block: 20 A Output from outlet: 15 A |
| Dimensions, mass |
320 mm (12.60 in) W × 110 mm (4.33 in) H × 253 mm (9.96 in) D, 4.5 kg (158.7 oz) |
| Supplied accessories |
TEST LEAD L2200 (Red ×1, Black ×1) ×1 set, ENCLOSURE PROBE 9195 ×1, Instruction manual ×1, Users manual ×1, Power cord ×3, Spare fuse for measurement line ×1 |
|
 |
| ST5540, ST5541 List of functions |
| Item |
ST5540 |
ST5541 |
| Network |
Network A (Electrical Appliances and Materials Safety Act) |
 |
 |
| Network B (Medical-use electrical devices) |
 |
- |
| Network C (IEC 60990) |
 |
 |
| Network D (UL) |
 |
 |
| Network E (General-purpose 1) |
 |
 |
| Network F (General-purpose 2) |
 |
 |
| Network G (IEC 61010-1) |
 |
 |
Major functions |
Power on polarity switching function |
 |
 |
| Rated current 20 A |
 |
 |
| Function for checking for blown fuses |
 |
 |
| Frequency band switching |
 |
- |
| 110% voltage output terminal (T3 terminal) |
 |
- |
| S10, S12, S13, E terminal |
 |
- |
|
|
|
| Item |
ST5540 |
ST5541 |
Testing leakage current mode |
Earth leakage current |
 |
 |
| Touch current |
 |
 |
| Patient auxiliary current |
 |
- |
| Patient leakage current |
 |
- |
| Total patient leakage current |
 |
- |
| Free current |
 |
 |
| Enclosure - Earth leakage current |
 |
 |
| Enclosure - Enclosure leakage current |
 |
 |
| Enclosure - Line leakage current |
 |
 |
| Patient leakage current I |
 |
- |
| Patient leakage current II |
 |
- |
| Patient leakage current III |
 |
- |
|
|
|