| Clamp Sensors (Wide-Bandwidth and High-Precision Current Measurement Possible) |
AC/DC CURRENT SENSOR CT6865 |
|
 |
|
|
 |
CAT III 1000V |
|
 |
 |
|
|
 |
 |
| Wide-Bandwidth, High-Precision and Large Current Measurement Possible |
 |
- 1000A large current measuring applications in the fields of EV and HEV (hybrid electric vehicles)
- An unparalleled characteristics in 1000 A class sensor, Operating temperature range: -30°C to 85°C
- Super high precision, ±0.06% amplitude accuracy, ±0.2 degree phase accuracy
- Wide-bandwidth DC to 20 kHz excellent frequency characteristics
- Applications in generating electricity by the sun light, a battery charge and discharge measurement and inverter secondary circuit measurement
- For observing waveforms to be used with the Oscilloscopes or MEMORY HiCORDERs (use with the 9555-10)
|
 |
| Combination use |
 |
 |
 |
 |
 |
POWER ANALYZER 3390 |
MOTOR / HARMONIC HiTESTER3194 |
POWER HiTESTER 3193 |
MEMORY HiCORDER series |
| Basic specifications (accuracy guaranteed for 1 year) |
 |
| Rated input current |
1000 A AC/DC |
| Max. allowable input |
1200 A AC/DC (Continuous 1800 A peak, up to 100 Hz, up to 40 °C (104 °F), other requires derating characteristics) |
| Frequency characteristic |
Amplitude: DC to 20 kHz, Phase: DC to 1 kHz |
| Amplitude and Phase accuracy |
DC ±0.05 % rdg. ±0.01 % f.s. (Phase: Not be defined)
16 Hz ≤ f ≤ 66 Hz ±0.05 % rdg. ±0.01 % f.s., Phase: ±0.2 deg
Amplitude is defined to 20 kHz, Phase is defined to 1 kHz |
| Power consumption |
7 VA max. (at 1000 A/55 Hz, ±12 V power requirement) |
| Output voltage |
2 V /rated current value (voltage output with the Sensor Unit 9555-10, use with a device having a 1 M-ohm input resistance or higher) |
| Max. rated voltage to earth |
AC/DC 1000 V (50/60 Hz, CAT III) |
| Core diameter |
φ36mm (1.42in) |
| Operating temperature, humidity |
-30°C to +85°C (-22°F to 185°F), 80% rh or less (with no condensation) |
| Power requirements |
DC ±11 V to ±15 V (Power suppled via the 9555-10, 9555-10 requirement with 100 to 240 V AC) |
| Dimensions, mass |
160mm (6.30in) W × 112mm (4.41in) H × 50mm (1.97in) D, 980g (34.6oz), cord length 3m (9.84ft) |
| Supplied accessories |
Instruction manual×1, Mark bands×6 |
|
 |
| Note: Connect and power up Clamp-on sensor to use in combination with the oscilloscope, or the MEMORY HiCORDER |
| 9555-10 Basic specifications (Power supply) |
 |
| Compatible models |
Model CT6865, CT6863, CT6862, 9709, 9279, 9278, 9277, 9272-10, 9272, 9271, 9270, one unit |
| Output |
BNC terminal, output signal from sensor |
| Power supply |
AC adapter 9418-15, AC 100 to 240V, 50/60Hz, 20VA Max. |
| Dimensions, mass |
42mm (1.65in)W × 82mm (3.23in)H × 132mm (5.20in)D, 600g (21.2oz) |
| Supplied accessories |
Instruction manual×1, AC ADAPTER 9418-15×1 | |
| Model CT6865 Device Combination Table |
Rated current derating to frequency and temperature |
 |
| Compatible models |
Combination status |
| Model 3390 |

Understand 500 A rated sensor, so requires to set CT ratio: 2 |
| Power supply model 9555-10, 9555 |
OK |
| Model 8971 for the MR8847-01s |

Understand 500 A rated sensor, so requires to set CT ratio: 2, need the CONVERSION CABLE 9318
Limit to the number of connectable sensor with the 8847/MR8847-01s : 7 |
| Input unit model 9602 for the 3193/3194 |

Understand the model 9279 (500 A rated), so requires to set CT ratio: 2 |
| Model 8951 for the 8855 |

Understand 500 A rated sensor, so requires to set CT ratio: 2, need the CONVERSION CABLE 9318
Limit to the number of connectable sensor with the 8855 : 7 |
| Model 8940 for the 8860-50/8861-50, 8841/42, 8835-01, 8826 |

Understand 500 A rated sensor, so requires to set CT ratio: 2, need the CONVERSION CABLE 9705 and the 9318
Limit to the number of connectable sensor with the 8860-50/ 8861-50 : 8, with the 8835-01: 4 |
|
 |

 |
|
|