Japanese Chinese Korea
AC/DC CURRENT SENSOR CT6865 < Current Probes/Clamp Sensors < Products
Clamp Sensors (Wide-Bandwidth and High-Precision Current Measurement Possible)

AC/DC CURRENT SENSOR CT6865

CE CAT III 1000V
OVERVIEW OPTION  
Wide-Bandwidth, High-Precision and Large Current Measurement Possible
  • 1000A large current measuring applications in the fields of EV and HEV (hybrid electric vehicles)
  • An unparalleled characteristics in 1000 A class sensor, Operating temperature range: -30°C to 85°C
  • Super high precision, ±0.06% amplitude accuracy, ±0.2 degree phase accuracy
  • Wide-bandwidth DC to 20 kHz excellent frequency characteristics
  • Applications in generating electricity by the sun light, a battery charge and discharge measurement and inverter secondary circuit measurement
  • For observing waveforms to be used with the Oscilloscopes or MEMORY HiCORDERs (use with the 9555-10)
Combination use
POWER ANALYZER 3390 MOTOR / HARMONIC HiTESTER 3194 POWER HiTESTER 3193 MEMORY HiCORDER 8847
POWER ANALYZER
3390
MOTOR / HARMONIC
HiTESTER3194
POWER HiTESTER
3193
MEMORY HiCORDER
series
Basic specifications (accuracy guaranteed for 1 year)
Rated input current 1000 A AC/DC
Max. allowable input 1200 A AC/DC (Continuous 1800 A peak, up to 100 Hz, up to 40 °C (104 °F), other requires derating characteristics)
Frequency characteristic Amplitude: DC to 20 kHz, Phase: DC to 1 kHz
Amplitude and Phase accuracy DC ±0.05 % rdg. ±0.01 % f.s. (Phase: Not be defined)
16 Hz ≤ f ≤ 66 Hz ±0.05 % rdg. ±0.01 % f.s., Phase: ±0.2 deg
Amplitude is defined to 20 kHz, Phase is defined to 1 kHz
Power consumption 7 VA max. (at 1000 A/55 Hz, ±12 V power requirement)
Output voltage 2 V /rated current value (voltage output with the Sensor Unit 9555-10, use with a device having a 1 M-ohm input resistance or higher)
Max. rated voltage to earth AC/DC 1000 V (50/60 Hz, CAT III)
Core diameter φ36mm (1.42in)
Operating temperature, humidity -30°C to +85°C (-22°F to 185°F), 80% rh or less (with no condensation)
Power requirements DC ±11 V to ±15 V (Power suppled via the 9555-10, 9555-10 requirement with 100 to 240 V AC)
Dimensions, mass 160mm (6.30in) W × 112mm (4.41in) H × 50mm (1.97in) D, 980g (34.6oz), cord length 3m (9.84ft)
Supplied accessories Instruction manual×1, Mark bands×6
Note: Connect and power up Clamp-on sensor to use in combination with the oscilloscope, or the MEMORY HiCORDER
9555-10 Basic specifications (Power supply)
Compatible models Model CT6865, CT6863, CT6862, 9709, 9279, 9278, 9277, 9272-10, 9272, 9271, 9270, one unit
Output BNC terminal, output signal from sensor
Power supply AC adapter 9418-15, AC 100 to 240V, 50/60Hz, 20VA Max.
Dimensions, mass 42mm (1.65in)W × 82mm (3.23in)H × 132mm (5.20in)D, 600g (21.2oz)
Supplied accessories Instruction manual×1, AC ADAPTER 9418-15×1
Model CT6865 Device Combination Table Rated current derating to frequency and temperature
Compatible models Combination status
Model 3390
Understand 500 A rated sensor, so requires to set CT ratio: 2
Power supply model 9555-10, 9555 OK
Model 8971 for the MR8847-01s
Understand 500 A rated sensor, so requires to set CT ratio: 2, need the CONVERSION CABLE 9318
Limit to the number of connectable sensor with the 8847/MR8847-01s : 7
Input unit model 9602 for the 3193/3194
Understand the model 9279 (500 A rated), so requires to set CT ratio: 2
Model 8951 for the 8855
Understand 500 A rated sensor, so requires to set CT ratio: 2, need the CONVERSION CABLE 9318
Limit to the number of connectable sensor with the 8855 : 7
Model 8940 for the 8860-50/8861-50, 8841/42, 8835-01, 8826
Understand 500 A rated sensor, so requires to set CT ratio: 2, need the CONVERSION CABLE 9705 and the 9318
Limit to the number of connectable sensor with the 8860-50/ 8861-50 : 8, with the 8835-01: 4

OVERVIEW OPTION