Wide-Bandwidth and High-Precision Current Measurement Possible
  • Super high precision, ±0.06% amplitude accuracy, ±0.2 degree phase accuracy
  • Wide-bandwidth DC to 1 MHz (CT6862) excellent frequency characteristics
  • Applications in the fields of electric and hybrid electric vehicles
  • A wide operating temperature range is fit to the automobile measurement
  • Applications in generating electricity by the sun light, a battery charge and discharge measurement and inverter secondary circuit measurement
  • For observing waveforms to be used with the MEMORY HiCORDERs
Combination use
POWER ANALYZER 3390 MOTOR / HARMONIC HiTESTER 3194 POWER HiTESTER 3193 MEMORY HiCORDER MR8847-01
POWER ANALYZER
3390
MOTOR / HARMONIC
HiTESTER 3194
POWER HiTESTER
3193
MEMORY HiCORDER MR8847-01 series
Basic specifications (accuracy guaranteed for 1 year)
  CT6862 CT6863
Rated current 50 A AC/DC 200 A AC/DC
Max. allowable input 100 A continuous (requires derating at frequency or temperature) 400 A continuous (requires derating at frequency or temperature)
Frequency characteristics Amplitude: DC to 1 MHz
Phase: DC to 300 kHz
Amplitude: DC to 500 kHz
Phase: DC to 300 kHz
Amplitude and Phase accuracy DC ±0.05 % rdg. ±0.01 % f.s. (Phase: Not be defined)
16 Hz ≤ f ≤ 400 Hz ±0.05 % rdg. ±0.01 % f.s. (Phase: ±0.2 deg)
Be defined to 1 MHz
DC ±0.05 % rdg. ±0.01 % f.s. (Phase: Not be defined)
16 Hz ≤ f ≤ 400 Hz ±0.05 % rdg. ±0.01 % f.s. (Phase: ±0.2 deg)
Be defined to 500 kHz
Power supply 5 VA max. (at 50 A/55 Hz, ±12 V power requirement) 6 VA max. (at 50 A/55 Hz, ±12 V power requirement)
Output voltage 2 V/rated current range (voltage output with the Sensor Unit 9555-10, use with a device having a 1 Mohm input resistance or higher)
Max. rated voltage to earth AC/DC 1000 V (50/60 Hz, CAT III ) AC/DC 1000 V (50/60 Hz, CAT III )
Core diameter φ 24 mm (0.94 in) φ 24 mm (0.94 in)
Operating temperature, humidity -30°C to +85°C (-22°F to 185°F), 80% rh or less (with no condensation)
Power requirements DC ±11 V to ±15 V (Power suppled via the 9555-10, 9555-10 requirement with 100 to 240 V AC)
Dimensions, mass 70W (2.76 in) × 100H (3.94 in) × 53D (2.09 in) mm, Cord length: 3 m (9.84 ft), 340 g (12.0 oz) 70W (2.76 in) × 100H (3.94 in) × 53D (2.09 in) mm, Cord length: 3 m (9.84 ft), 350 g (12.3 oz)
Supplied accessories Mark bands × 6, Operating manual × 1
Note: Connect and power up Clamp-on sensor to use in combination with the oscilloscope, or the MEMORY HiCORDER
9555-10 Basic specifications (Power supply)
Compatible models Model CT6865, CT6863, CT6862, 9709, 9279, 9278, 9277, 9272-10, 9272, 9271, 9270, one unit
Output BNC terminal, output signal from sensor
Power supply AC adapter 9418-15, AC 100 to 240V, 50/60Hz, 20VA Max.
Dimensions, mass 42mm (1.65in)W × 82mm (3.23in)H × 132mm (5.20in)D, 600g (21.2oz)
Supplied accessories AC adapter 9418-15 × 1
Model CT6862/6863 Device Combination Table Rated current derating to frequency and temperature
Compatible models CT6862
Combination status
CT6863
Combination status
Model 3390 OK OK
Power supply model 9555-10, 9555 OK OK
Model 8971 for the 8847 OK OK
Input unit model 9602 for the 3193/3194
In order to use the AC/DC CURRENT SENSOR Model CT6862 with Model 3193/ 3194, a firmware upgrade of Model 3193/ 3194 is required
OK
Model CT6863 is recognized as the UNIVERSAL CLAMP ON CT Model 9278 by Model 3193/ 3194, but operability is supported
Model 8951 for the 8855 No (Need Conversion Cable the 9318) Substitute for the 9278
Model 8940 for the 8860-50/8861-50, 8841/42, 8835-01, 8826 No (Need Conversion Cable the 9705 and the 9318) Substitute for the 9278
OVERVIEW OPTION DOWNLOAD CATALOG