Current Probes/Clamp Sensors Index
<
Products
Current Probes/Clamp Sensors Index
All information correct as of November 1, 2002. All specifications are subject to change without notice.
Discontinued Products
For Oscilloscope/ MEMORY HiCORDERs, DC to 100MHz wide-band for observing waveforms
CLAMP ON PROBE 3276
CLAMP ON PROBE 3275
CLAMP ON PROBE 3274
CLAMP ON PROBE 3273-50
DC to 100MHz (-3dB)
30Arms maximum
0.1V/A output
Ø 5mm (0.20in) dia.
DC to 2MHz (-3dB)
500Arms maximum
0.01V/A output
Ø 20mm (0.79in) dia.
DC to 10MHz (-3dB)
150Arms maximum
0.01V/A output
Ø 20mm (0.79in) dia.
DC to 50MHz (-3dB)
30Arms maximum
0.1V/A output
Ø 5mm (0.20in) dia.
For monitoring load current levels and observing waveforms with the MEMORY HiCORDERs
(50/60Hz use)
CLAMP ON PROBE 9132-50
CLAMP ON PROBE 9018-50
CLAMP ON PROBE 9010-50
40Hz to 1kHz
AC 20A to 1000A range
AC 0.2V/ range output
Ø 55mm(2.17in) dia.
40Hz to 3kHz
Phase: 40Hz to 3kHz
AC 10A to 500A range
AC 0.2V/range output
Ø 46mm(1.81in) dia.
40Hz to 1kHz
AC 10A to 500A range
AC 0.2V/range output
Ø 46mm(1.81in) dia.
For current input to be used with wide-band Power Meters
(3193/3194)
,
For observing waveforms to be used with the MEMORY HiCORDERs
AC/DC CURRENT SENSOR 9709
UNIVERSAL CLAMP ON CT 9279
UNIVERSAL CLAMP ON CT 9278
UNIVERSAL CLAMP ON CT 9277
CLAMP ON SENSOR 9272-10
DC to 100kHz
Phase: DC to 100kHz
500A rated
2V/500A output
Ø 36mm(1.42in) dia.
DC to 20kHz
Phase: DC to 20kHz
500A rated
2V/500A output
Ø 40mm(1.57in) dia.
DC to 100kHz
Phase: DC to 100kHz
200A rated
2V/200 A output
Ø 20mm(0.79in) dia.
DC to 100kHz
Phase: DC to 100kHz
20A rated
2V/20A output
Ø 20mm(0.79in) dia.
1Hz to 100kHz
Phase: 5Hz to 50kHz
20A or 200A rated
2V/20A, 2V/200A output
Ø 46mm(1.81in) dia.
Power supply for current probes
POWER SUPPLY 3272
POWER SUPPLY 3269
SENSOR UNIT 9555-10
Power supply for the 3273-50/ 3274/ 3275/ 3276
Single sensor connectable
Power supply for the 3273-50/ 3274/ 3275/ 3276
Connect up to four sensors
Power supply for the 9270, 9271, 9272/-10, 9277, 9278, 9279, 9709
Single sensor connectable
For current input to be used with Power Meter
(3169)
,
Power Quality Analyzer
(3196, 3197)
For observing waveforms with the MEMORY HiCORDERs
CLAMP ON SENSOR 9695-02
CLAMP ON SENSOR 9695-03
CLAMP ON SENSOR 9669
FLEXIBLE CLAMP ON SENSOR 9667
CLAMP ON SENSOR 9661
40Hz to 5kHz
Phase: 45Hz to 5kHz
AC 50A rated input
AC 10mV/A output
Ø 15mm(0.59in) dia.
40Hz to 5kHz
Phase: 45Hz to 5kHz
AC 100A rated input
AC 1mV/A output
Ø 15mm(0.59in) dia.
40Hz to 5kHz
Phase: 45Hz to 5kHz
AC 1000A rated input
AC 0.5mV/A output
Ø 55mm(2.17in) dia.
10Hz to 20kHz
Phase: 45Hz to 66Hz
AC 500/5000A rated input
AC 500mV f.s. output
Ø 254mm(10.0in) dia.
40Hz to 5kHz
Phase: 45Hz to 5kHz
AC 500A rated input
AC 1mV/A output
Ø 46mm(1.81in) dia.
CLAMP ON SENSOR 9660
CLAMP ON SENSOR 9694
40Hz to 5kHz
Phase: 45Hz to 5kHz
AC 100A rated input
AC 1mV/A output
Ø 15mm(0.59in) dia.
40Hz to 5kHz
Phase: 45Hz to 5kHz
AC 50A rated input
AC 10mV/A output
Ø 15mm(0.59in) dia.
To be used with the 3196, 3197
To use with the 3638-20
CLAMP ON LEAK SENSOR 9675
CLAMP ON LEAK SENSOR 9657-10
CLAMP ON LEAK SENSOR 9657
CLAMP ON LEAK SENSOR 9658
CLAMP ON LEAK SENSOR 9659
40Hz to 5kHz
AC 10A rated input
AC 100mV/A output
Ø 30mm(1.18in) dia.
40Hz to 5kHz
AC 10A rated input
AC 100mV/A output
Ø 40mm(1.57in) dia.
45Hz to 66Hz
AC 1A rated input
AC 25mV/A output
Ø 40mm(1.57in) dia.
45Hz to 66Hz
AC 1A rated input
AC 25mV/A output
12x30mm (0.47x1.18in) dia.
45Hz to 66Hz
AC 1A rated input
AC 25mV/A output
30x150mm (1.18x5.91in) dia.
Not CE-marked
For monitoring load current levels, to be used with the Clamp Logger 3636-20 or MICRO HiCORDERs 8205-10/8206-10 only
CLAMP ON SENSOR 9668
CLAMP ON SENSOR 9651
CLAMP ON SENSOR 9650
Can not use with the 3636-20
40Hz to 1kHz
Primary: AC 1000A
Secondary: AC 1000mA
Max. input: AC 1000A
Ø 55mm(2.17in) dia.
40Hz to 1kHz
Primary: AC 500A
Secondary: AC 500mA
Max. input: AC 600A
Ø 46mm(1.81in) dia.
40Hz to 1kHz
Primary: AC 100A
Secondary: AC 100mA
Max. input: AC 130A
Ø 15mm(0.59in) dia.