| Clamp Sensors (Wide-Bandwidth and High-Precision Current Measurement Possible) |
AC/DC CURRENT SENSOR 9709 |
|
 |
|
|
 |
CAT III 1000V |
|
 |
 |
|
|
 |
 |
| High-precision sensors to view waveforms or to use with power meters (for AC/DC) |
 |
- Super high precision, ±0.06% amplitude accuracy, ±0.2 degree phase accuracy
- Wide-bandwidth DC to 100 kHz excellent frequency characteristics
- Applications in the fields of electric and hybrid electric vehicles
- Applications in generating electricity by the sun light, a battery charge and discharge measurement and inverter secondary circuit measurement
- For observing waveforms to be used with the MEMORY HiCORDERs
|
 |
| Combination use |
 |
 |

CT6862: available soon |

CT6862: available soon |
 |
POWER ANALYZER
3390 |
MOTOR / HARMONIC
HiTESTER
3194 |
POWER HiTESTER
3193 |
MEMORY HiCORDER
8847 |
 |
| Basic specifications (accuracy guaranteed for 6 months, 10 minutes of warm-up time) |
 |
| Rated current |
500 A AC/DC |
| Max. allowable input |
700 Arms (1000 Apeak, requires derating at frequency) |
| Frequency characteristics |
Amplitude: DC to 100 kHz, Phase: DC to 100 kHz |
| Amplitude and Phase accuracy |
DC, 45 Hz ≤ f ≤ 66 Hz (±0.05 % rdg. ±0.01 % f.s. (Phase: ±0.2 deg)
Be defined to 100 kHz |
| Power consumption |
5 VA max. (at 500 A/55 Hz, ±12 V power requirement) |
| Output voltage |
2 V/rated current range (voltage output with the Sensor Unit 9555-10, use with a device having a 1Mohm input resistance or higher) |
| Max. rated voltage to earth |
1000 V AC/DC (50/60 Hz, CAT III ) |
| Core diameter |
φ 36 mm (1.42 in) |
| Operating temperature, humidity |
0°C to +50°C (32°F to 122°F), 80% rh or less (with no condensation) |
| Power requirements |
DC ±11 V to ±15V (Power suppled via the 9555-10, 9555-10 requirement with 100 to 240 V AC) |
| Dimensions, mass |
160W (6.30 in) × 112H (4.41 in) × 50D (1.97 in) mm, Cord length: 3 m (9.84 ft), 850 g (30.0 oz) |
| Supplied accessories |
Mark bands × 6, Operating manual × 1 |
|
 |
| Note: Connect and power up Clamp-on sensor to use in combination with the oscilloscope, or the MEMORY HiCORDER |
| 9555-10 Basic specifications (Power supply) |
 |
| Compatible models |
Model 9270, 9271, 9272, 9272-10, 9277, 9278, 9279, 9709, CT6862, CT6863, one unit |
| Output |
BNC terminal, output signal from sensor |
| Power consumption |
AC adapter 9418-15, AC 100 to 240V, 50/60Hz, 20VA Max. |
| Dimensions, mass |
42mm (1.65in)W × 82mm (3.23in)H × 132mm (5.20in)D, 600g (21.2oz) |
| Supplied accessories |
AC adapter 9418-15 × 1 |
|
| Model 9709 Device Combination Table |
9709 Characteristics |
 |
| Compatible models |
Combination status |
| Model 3390 |
OK |
| Power supply model 9555-10, 9555 |
OK |
| Input unit model 9602 for the 3193/3194 |
OK (Model 9709 is recognized as the Model 9279) |
| Model 8971 for the 8847 |
OK |
| Model 8951 for the 8855 |
(Need Conversion Cable the 9318) Substitute for the 9279 |
| Model 8940 for the 8860/61-50, 8841/42, 8835-01, 8826 |
(Need Conversion Cable the 9705 and the 9318) Substitute for the 9279 |
|
 |

Rated current derating to frequency |
|
|