Japanese Chinese Korea
h_clampfield.jpg
FLEXIBLE CLAMP ON SENSOR 9667 < Clamp Sensors < Products
Clamp Sensors (Current sensor for Models 3169 and 3196)

FLEXIBLE CLAMP ON SENSOR 9667

CE DCL

CAT III 1000V
OVERVIEW OPTION DOWNLOAD CATALOG  
Measure large currents with the PQA 3196 and MEMORY HiCORDER 8860 Series
  • Lightweight, hollow-coil sensor precludes overheating even when sensing large currents
  • Even flexible enough for complicated wiring
Basic specifications
Rated input current 5000A to 500A AC 500A to 50A AC
Rated output current 500mV AC f.s. (0.1mV AC/A) 500mV AC f.s. (1mV AC/A)
Amplitude accuracy ±2.0% rdg. ±1.5mV (45 to 66 Hz, minimum input 10% of range)
Phase accuracy ±1 degree (45 to 66 Hz)
Max. allowable input Continuous 10000 A AC (45 to 66 Hz)
Frequency characteristics 10 Hz to 20 kHz ±3 dB (deviation from accuracy)
Max. rated voltage to earth 1000 V AC rms (insulated wire)
Core jaw dia. φ 254 mm (10 inch)
Power requirement LR03 (AAA) × 4, continuous use 7 days, or AC adapter 9445-02/ 9445-03
Dimensions and mass Sensor: 910 mm (35.83 in) length, Control unit: 57.5W × 86.5H × 30D mm (2.26 in × 3.41 in × 1.18 in), 450 g (15.9 oz), Cord length from sensor to unit: 2m (6.56 ft), Output cord 1 m (3.28 ft)
Accessories LR03 (AAA) alkaline batteries × 4
Note: In addition to the Power Quality Analyzer 3196, the 9667 can also be used as a current sensor with Model 3169 and voltage input recorders.
Use with these products
PQA series MEMORY HiCORDER series CLAMP ON POWER HiTESTER series
PQA series MEMORY HiCORDER series CLAMP ON POWER HiTESTER series
OVERVIEW OPTION DOWNLOAD CATALOG