CLAMP ON SENSOR 9661, 9669

CE DCL
Max. circuit voltage
600 V rms insulated wire

3196

8860-50
   
3169
 
OVERVIEW  
Use with Power Meter for large current measurement
  • For inverter devices or commercial power lines
  • Up to 500 A, or 1000 A measure
  • Basic specifications (accuracy guaranteed for 1 year)
      9661 9669
    Rated primary current AC 500 A AC 1000 A
    Output voltage AC 500 mV f.s. (AC 1 mV/A) AC 500 mV f.s. (AC 0.5 mV/A)
    Amplitude accuracy ±0.3 % rdg. ±0.01 % f.s. (45 to 66 Hz, f.s.= rated primary current) ±1.0 % rdg. ±0.01 % f.s. (45 to 66 Hz, f.s.= rated primary current)
    Phase accuracy ±0.5 deg. (at 45 Hz to 5 kHz) ±1 deg. (at 45 Hz to 5 kHz)
    Max. allowable input AC 550 A continuous (45 to 66 Hz) AC 1000 A continuous (45 to 66 Hz)
    Frequency characteristics 40 Hz to 5 kHz: ± 1.0%
    (Add to amplitude accuracy)
    40 Hz to 5 kHz: ± 2.0%
    (Add to amplitude accuracy)
    Max. rated voltage to earth AC 600 V rms (insulated wire) AC 600 V rms (insulated wire)
    Core jaw diameter φ 46 mm (1.81 in) φ 55 mm (2.17 in) or 80 mm (3.15 in) × 20 mm (0.79 in) busbar
    Dimensions, mass 77 mm (3.03 in)W × 151 mm (5.94 in) H × 42 mm (1.65 in)D, Cord length: 3 m (9.84 ft), 380 g (13.4 oz) 99.5 mm (3.92 in)W × 188 mm (7.40 in)H × 42 mm (1.65 in)D, Cord length: 3 m (9.84 ft), 590 g (20.8 oz)
    Note: In addition to the Power Quality Analyzer 3196, can also be used as a current sensor with Model 3169 and voltage input recorders.