| Clamp Sensors (Current sensor for Models 3169 and 3196) |
CLAMP ON SENSOR 9660 |
|
 |
|
 |
 |
CAT III 300 V |

 POWER QUALITY ANALYZER 3196 |
|
 |
 |
|
|
 |
| OVERVIEW |
 |
|
 |
| Clamp-on Sensors for the POWER QUALITY ANALYZER 3196 and CLAMP ON POWER HiTESTER 3169 |
 |
| For input up to AC 500A, select our Model 9661, and for smaller currents of up to AC 100A, select Model 9660. Both sensors are designed with a safety barrier to protect the user from being in direct contact with live conductors and completely meet all CE marking requirements. |
 |
| Basic specifications |
 |
| Rated input current |
100 A AC |
| Rated output current |
0.1 V AC |
| Accuracy (at 45 to 66 Hz) |
Amplitude: ±0.5 % rdg. ±0.2 % f.s. , Full scale (f.s.) is the 3196 range value, Phase: ±1 ° or less (at 90 A or less), ±1.3 ° or less (at 90 A to 100 A) |
| Frequency characteristics |
66 Hz to 5 kHz (±1 % or less from accuracy) |
| Max. allowable input |
continuous 130 A rms (45 to 66 Hz) |
| Max. circuit voltage |
300 V AC rms (insulated wire) |
| Core jaw dia. |
Ø15 mm(0.59 in) |
| Dimensions, mass |
46 mm(1.81 in)W × 135 mm(5.31 in)H × 21 mm(0.83 in)D, 230 g (8.1 oz), cord length: 3 m(9.84 ft) |
|
 |
| OVERVIEW |
 |
|
|