| Clamp Sensors (For power line current measurement -50/60 Hz use-) |
CLAMP ON PROBE 9132 |
|
 |
|
 |
Bare BANANA terminal |

 Model 9132-10
Insulated BNC terminal |
|
 |
 |
|
|
 |
| OVERVIEW |
 |
|
 |
| Easy-to-use, current to voltage transformer |
 |
- Intended primarily for application as an input sensor for a recorder
- A secondary output provides an AC voltage waveform, and can be connected to an input impedance over 1M-ohm
|
 |
| Basic specifications |
 |
| Rated current |
1000 A AC (20 A to 1000 A full scale, 6 ranges selectable) |
| Frequency band width |
40 to 1 kHz (±1 % max.) |
| Accuracy (at 50 or 60 Hz) |
±3 % rdg. ±0.5 mV |
| Output rate |
0.2 V AC at full scale range (waveform output), Output terminal: Bare Banana |
| Max. circuit voltage |
600 V AC rms (insulated wire) |
| Core jaw dia. |
Ø55 mm(2.17 in), or 80 mm(3.15 in) busbar |
| Power supply |
None |
| Dimensions, mass |
99 mm(3.90 in)W × 192 mm(7.56 in)H × 33 mm(1.30 in)D, 580 g (20.5 oz), cord length: 3 m(9.84 ft) |
| Accessories |
CARRYING CASE 9148 (1) |
|
 |