9132-50 |
9010-50 |
| Rated current |
AC 20/50/100/200/500/1000 A |
AC 10/20/50/100/200/500 A |
| Accuracy |
±3% rdg. ±0.2% f.s. (45 to 66Hz) |
±2% rdg. ±1% f.s. (45 to 66Hz) |
| Frequency characteristics |
Add to amplitude accuracy for frequencies from 40 to 1kHz: ± 1% rdg. |
Add to amplitude accuracy for frequencies from 40 to 1kHz: ±6% rdg. (at 10A and 20A range) ±3% rdg. (for 50A range and above) |
| Output rate |
0.2V AC f.s. (f.s.=setting rage)
(Connect to a voltage input device providing a high input impedance of 1MΩ) |
| Max. current input |
(For 40Hz to500 Hz: 100%, and for 500Hz to 1kHz: within 90% of derating)
1000Arms continuous (all ranges) |
(For 40Hz to 100Hz: 100%, and for 100Hz to 1kHz: within 50% of derating)
150Arms continuous (10/20/50A ranges)
400Arms continuous (100/200A ranges)
650Arms continuous (500A range) |
| Max. circuit voltage |
600Vrms (Insulated conductor) |
600Vrms (Insulated conductor) |
| Diameter |
Ø 55mm(2.17in), or 20mm(0.79in) × 80mm(3.15in) busbar |
Ø 46mm(1.81in) |
| Dimensions, mass |
100mm(3.94in)W × 224mm(8.82in)H × 35mm(1.38in)D, 600g(21.2oz), cord length: 3m(9.84ft) |