Japanese Chinese Korea
MEMORY HiCORDER 8860-50, 8861-50 < Recorder < Products
Recorder (For simultaneous recording of multiple signals)

MEMORY HiCORDER 8860-50, 8861-50

OVERVIEW OPTION DOWNLOAD CATALOG Version Upgrade EXTRAS
Factory-installed option *Must specify when ordering
Note: Memory boards are not built in as a standard feature. Choose one board for Model 8860-50, and two of the same capacity for the 8861-50, for factory pre-installation.
MEMORY BOARD 9715-50
MEMORY BOARD 9715-50 32 Megaword capacity
MEMORY BOARD 9715-51
MEMORY BOARD 9715-51 128 Megaword capacity
MEMORY BOARD 9715-52
MEMORY BOARD 9715-52 512 Megaword capacity
MEMORY BOARD 9715-53
MEMORY BOARD 9715-53 1 Gigaword capacity
HD UNIT 9718-50
HD UNIT 9718-50 Factory-installed option. 80 GB
MEMORY BACK UP UNIT 9719-50

Factory-installed option. Internal type.
DC POWER UNIT 9684
DC POWER UNIT 9684 Factory-installed option - not user installable, built in on the bottom case.12V DC drive.
* Only one of either the DC Power Unit 9684 or Probe Power Unit 9687 can be installed at any one time. Please contact your HIOKI representative if concurrent installation is required.
Input modules
Input cables are not supplied. Please purchase the appropriate cable for the intended application.
Install by inserting into the main unit. Can be replaced by user.
ANALOG UNIT 8956
ANALOG UNIT 8956 2ch, Voltage input, DC to 10MHz band width
Details
HIGH RESOLUTION UNIT 8957
HIGH RESOLUTION UNIT 8957 2ch, Voltage input, DC to 200kHz band width, built in filter for FFT
Details
16ch SCANNER UNIT 8958
16ch SCANNER UNIT 8958 16ch, Voltage or Temperature input with thermocouple
Details
DC/RMS UNIT 8959
DC/RMS UNIT 8959 2ch, Voltage, DC to 400kHz, or RMS rectifier DC/20 to 100kHz
Details
STRAIN UNIT 8960
STRAIN UNIT 8960 2ch, Distortion measurement for strain gauge converter
Details
HIGH VOLTAGE UNIT 8961
HIGH VOLTAGE UNIT 8961 2ch, Voltage input, DC/RMS selectable
Note: Maximum 4units in one the Model 8861-50
Details
ANALOG UNIT 8936
ANALOG UNIT 8936 2ch, Voltage input, DC to 400kHz band width
Details
VOLTAGE/TEMP UNIT 8937
VOLTAGE/TEMP UNIT 8937 2ch, Voltage or Temperature input with thermocouple
Details
FFT ANALOG UNIT 8938
FFT ANALOG UNIT 8938 2ch, Voltage input, DC to 400kHz band width, built in filter for FFT
Details
STRAIN UNIT 8939
STRAIN UNIT 8939 2ch, Distortion measurement for strain gauge converter
Details
F/V UNIT 8940
F/V UNIT 8940 2ch, Frequency, Voltage input, Current input with clamp-on sensor
Details
4ch ANALOG UNIT 8946
4ch ANALOG UNIT 8946 4ch, Low voltage input, DC to 100kHz band width
Details
CHARGE UNIT 8947
CHARGE UNIT 8947 2 ch, Charge-output type piezoelectric acceleration pick-up sensor, Acceleration pick-up sensor with an internal preamp
Details
Logic signal measurement
LOGIC PROBE 9327
LOGIC PROBE 9327 4-channel type, for voltage/contact signal ON/OFF detection (response time 0.1μsec or higher, miniature terminal type)
Details
LOGIC PROBE MR9321-01
LOGIC PROBE MR9321-01 4 isolated channels, ON/OFF detection of AC/DC voltage (miniature terminal type)
LOGIC PROBE 9320-01
LOGIC PROBE 9320-01 4-channel type, for voltage/contact signal ON/OFF detection (response time 0.5μsec, miniature terminal type)
Details
CONVERSION CABLE 9323
CONVERSION CABLE 9323 Used for connecting the 9320/9321/MR9321 and 8860 series MEMORY HiCORDERs, because the terminal shapes are different.
* This cable is not required for the small-terminal types 9327, 9320-01, 9321-01, and MR9321-01.
Voltage measurement (Voltage is limited to the specifications of the input modules in use)
CONNECTION CORD L9790
CONNECTION CORD L9790 Flexible φ 4.1 mm (0.16 in) thin dia. cable allowing for up to 600 V input. 1.8 m (5.91 ft) length
* The end clip is sold separately.
Tip expansion
ALLIGATOR CLIP L9790-01
ALLIGATOR CLIP L9790-01 Red/black set attaches to the ends of the cables L9790
Tip expansion
CONTACT PIN 9790-03
CONTACT PIN 9790-03 Red/black set attaches to the ends of the cables L9790
Tip expansion
GRABBER CLIP 9790-02
GRABBER CLIP 9790-02 Red/black set attaches to the ends of the cables L9790
* When this clip is attached to the end of the L9790, input is limited to 300 V. Red/black set
Tip expansion
CONNECTION CORD L9198
CONNECTION CORD L9198 φ 5.0 mm (0.20 in) dia. cable allowing for up to 300 V input. 1.7 m (5.58 ft) length, Small alligator clip
Tip expansion
100:1 PROBE 9666
100:1 PROBE 9666 Max. rated voltage to earth is same as for input module, max. input voltage 5kV peak (up to 1MHz), 1.5m (4.92ft) length
Details
10:1 PROBE 9665
10:1 PROBE 9665 Max. rated voltage to earth is same as for input module, max. input voltage 1kV rms (up to 500kHz), 1.5m (4.92ft) length
Details
CONNECTION CORD 9197
CONNECTION CORD 9197 φ 5.0 mm (0.20 in) dia., cable allowing for up to 600 V input. 1.8 m (5.91ft) length, a detachable large alligator clips are bundled
GRABBER CLIP 9243
GRABBER CLIP 9243 Attaches to the tip of the Cord 9197, Red/ Black set, 196 mm (7.72 in) length
High-Voltage measurement (for use with power supply)
DIFFERENTIAL PROBE 9322
DIFFERENTIAL PROBE 9322 For up to 2kV DC or 1kV AC. Use with either AC Adapter 9418-15, or Probe Power Unit 9687 and Power Cord 9248.
Details
PROBE POWER UNIT 9687
PROBE POWER UNIT 9687 Factory-installed option - not user installable, built in on the bottom case. Simultaneously power up to 8 units of ifferential Probe 9322. (Max. 3 A output)
AC ADAPTER 9418-15
AC ADAPTER 9418-15 For powering Differential probe 9322, 100 to 240V AC
POWER CORD 9248
POWER CORD 9248 to connect Differential probe 9322 and Probe power unit 9687, 70cm (2.3ft) length
Current measurement (To connect the clamp-on sensor via the conversion cable, The 3274, 3275, and 3276 cannot be used for the F/V UNIT 8940)
UNIVERSAL CLAMP ON CT 9279
UNIVERSAL CLAMP ON CT 9279 Observe waveforms from DC to distorted AC. DC to 20kHz response, input 500A/output 2V AC, Not CE marked
Details
UNIVERSAL CLAMP ON CT 9278
UNIVERSAL CLAMP ON CT 9278 Observe waveforms from DC to distorted AC. DC to 100kHz response, input 200A/output 2V AC
Details
UNIVERSAL CLAMP ON CT 9277
UNIVERSAL CLAMP ON CT 9277 Observe waveforms from DC to distorted AC. DC to 100kHz response, input 20A/output 2V AC
Details
SENSOR UNIT 9555-10
SENSOR UNIT 9555-10 Power supply unit for the 9272 to the 9279 clamp sensors, except for connecting to the F/V unit 8940, for signal output L9217 is necessary.
Details
CLAMP ON SENSOR 9272-10
CLAMP ON SENSOR 9272-10 Enables observation of AC current waveforms. Input: 1 to 100kHz, selectable 20 and 200A rms ranges, 2V AC output
Details
CONVERSION CABLE 9705
CONVERSION CABLE 9705 Use with the Conversion Cable 9318 to connect Model 9272-10 to the F/V Unit 8940. (Not necessary for when using the Model 9272 due to different output wiring specifications.)
CONVERSION CABLE 9318
CONVERSION CABLE 9318 To connect the 9272 to 9279 and the 8940
CONVERSION CABLE 9319
CONVERSION CABLE 9319 To connect the 3273-50 and the 8940
Note: cannot be used with the 3274, 3275, 3276 to connect the 8940 via this cable 9319
CLAMP ON PROBE 3273-50
CLAMP ON PROBE 3273-50 DC to 50MHz wideband response, mA-class current up to 30A rms
Details
Current measurement (Connect directly to the analog input module)
CLAMP ON PROBE 3276
CLAMP ON PROBE 3276 DC to 100MHz wideband response, mA-class current up to 30A rms
Details
CLAMP ON PROBE 3275
CLAMP ON PROBE 3275 DC to 2MHz wideband response, mA-class current up to 500A rms
Details
CLAMP ON PROBE 3274
CLAMP ON PROBE 3274 DC to 10MHz wideband response, mA-class current up to 150A rms
Details
CLAMP ON PROBE 3273-50
CLAMP ON PROBE 3273-50 DC to 50MHz wideband response, mA-class current up to 30A rms
Details
POWER SUPPLY 3272
POWER SUPPLY 3272 Connect and power up to one CLAMP ON PROBE to use in combination with voltage input modules
Details
POWER SUPPLY 3269
POWER SUPPLY 3269 Connect and power up to four CLAMP ON PROBEs to use in combination with voltage input modules
Details
PROBE POWER UNIT 9687
PROBE POWER UNIT 9687 Factory-installed option - not user installable, built in on the bottom case. Simultaneously power up to at least 5 units of Clamp on Probes 3273-50 to 3276 or Differential Probe 9322. (Actual number depends on combination of probes.)
* Either the DC power unit 9684 or the probe power unit 9687 may be used. If you want to use both at the same time, consult us.
Current measurement * Use for commercial power line, 50/60 Hz (Useless the power supply)
CLAMP ON PROBE 9018-50
CLAMP ON PROBE 9018-50 Enables observation of AC current waveforms. 40Hz to 3kHz response, input 10A to 500A range, output 0.2V AC/range
Details
CLAMP ON PROBE 9132-50
CLAMP ON PROBE 9132-50 Enables observation of AC current waveforms. 40Hz to 1kHz response, input 20A to 1000A range, output 0.2V AC/range
Details
Printer options
RECORDING PAPER 9231
RECORDING PAPER 9231 A4 width 216mm (8.50in) × 30m (98.43ft), 6rolls
RECORDING PAPER 9234
RECORDING PAPER 9234 A6 width 112mm (4.41in) × 18m (59.06ft), 10rolls
A4 PRINTER UNIT 8995
A4 PRINTER UNIT 8995 Factory-installed option. Either 8995 or 8995-01 printer can be installed. Printing width 200 mm (7.87 inch). Compatible recording paper: Model 9231
A6 PRINTER UNIT 8995-01
A6 PRINTER UNIT 8995-01 Factory-installed option. Either 8995 or 8995-01 printer can be installed. Printing width 100 mm (3.94 inch). Compatible recording paper: Model 9234
PC Software
MEMORY HiVIEWER 9725
MEMORY HiVIEWER 9725 Functions identical to those of the 8860s. Windows 2000/XP/Vista (32bit), Windows 7 (32/64bit)
Details
FlexPro
FlexPro FlexPro is a powerful data analysis and presentation software for importing and organizing data from the 8860-50 / 8861-50 Series.
Product Company: Weisang GmbH (Germany)
Email: info@weisang.com
URL: http://www.weisang.com/
WAVE PROCESSOR 9335
WAVE PROCESSOR 9335 Convert data, print and display waveforms. Windows 2000/XP/Vista (32-bit), Windows 7 (32/64-bit)
Note: Supports 8860-50/8860, 8861-50/8861 series MEM, REC and REC&MEM data recorded using single-axis sampling only
Details
Removable storage (CF card)
* PC Card Precaution
Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.
PC CARD 2G 9830
PC CARD 1G 9729 Supplied with PC Card adapter, 2GB capacity
Details
PC CARD 1G 9729
PC CARD 1G 9729 Supplied with PC Card adapter, 1GB capacity
Details
PC CARD 512M 9728
PC CARD 512M 9728 Supplied with PC Card adapter, 512MB capacity
Details
PC CARD 256M 9727
PC CARD 256M 9727 Supplied with PC Card adapter, 256MB capacity
Details
Other options
CONNECTION CORD L9217
CONNECTION CORD L9217 Insulated BNC connectors at both ends, Connects to insulated BNC connectors on input module. 1.7 m (5.58 ft) length
CONNECTION CORD 9165
CONNECTION CORD 9165 Cord has metallic BNC connectors at both ends, and connects to metallic BNC connectors. 1.5m (4.92ft) length, Not CE marked
CONVERSION ADAPTER 9199
CONVERSION ADAPTER 9199 Female banana terminals to BNC plug (output), use to connect to BNC terminal on Input Module
LAN CABLE 9642
LAN CABLE 9642 Straight Ethernet cable, supplied with straight to cross conversion cable, 5m (16.41ft) length
CARRYING CASE 9723
CARRYING CASE 9723 For only the 8860-50/8860, hard trunk type
CARRYING CASE 9724
CARRYING CASE 9724 For only the 8861-50/8861, hard trunk type
OVERVIEW OPTION DOWNLOAD CATALOG Version Upgrade EXTRAS