Japanese Chinese Korea
MEMORY HiCORDER 8855 < Recorder < Products
Recorder (For waveform capture of high-speed signals -Digital Oscilloscope Series)

MEMORY HiCORDER 8855

OVERVIEW OPTION DOWNLOAD CATALOG EXTRAS  
Products marked with an * (asterisk) do not have the CE mark
Specify upon order; factory installation only
MEMORY BOARD 9645
(Total 128 megawords) Expands instrument memory by 4 times its original size
MEMORY BOARD 9645-01
(Total 512 megawords) Expands instrument memory by 16 time its original size
HDD UNIT 9663
(20 GB) Note:The MO and HDD UNITs cannot be mounted on the unit at the same time
MO UNIT 9646

(1.3 GB, 640 MB to 128 MB)
Printer
PRINTER UNIT 8994
Specify upon order; factory installation only; printing width of 200 mm (7.87 in)
RECORDING PAPER 9231
216 mm(8.50 in) width × 30 m (98.43 ft), roll type, 6 rolls per set
*PAPER WINDER 220H
Paper width 70 mm (2.76 in) to 220 mm (8.66 in), using special-purpose AC adapter
Details
Input modules
Install or replace simply by inserting the module into the base unit
Note:Input cords are not provided. Please purchase the appropriate input cord for the probe type and application separately.
ANALOG UNIT 8950 ANALOG UNIT 8950

8951 VOLTAGE/CURRENT UNIT VOLTAGE / CURRENT UNIT 8951

DC/RMS UNIT 8952 DC/RMS UNIT 8952

HIGH RESOLUTION UNIT 8953-10 HIGH RESOLUTION UNIT 8953-10

VOLTAGE/TEMP UNIT 8954 VOLTAGE/TEMP UNIT 8954

F/V UNIT 8955 F/V UNIT 8955

Logic input
LOGIC PROBE 9327
LOGIC PROBE 9327 4 channels, ON/OFF detection of voltage/contact signals (high-speed type for use with the 8855)
Details
LOGIC PROBE 9321-01
VOLTAGE/TEMP UNIT 8954 4 isolated channels, ON/OFF detection of AC/DC voltage (small terminal type)
Details
ADAPTER CABLE 9323
Used for connecting the 9321 (large terminal type) and the 8855 MEMORY HiCORDER (small terminal type), because the terminal shapes are different.
* This cable is not required for the small-terminal types 9327, 9320-01, and 9321-01.
Voltage measurement
CONNECTION CORD 9197
For up to 500 V, 1.8m (5.91ft)
Details
CONNECTION CORD 9198
For up to 300 V, 1.7m (5.58ft)
Details
10:1 PROBE 9665
Max. rated voltage to earth is same as for input module, Max. input voltage 1kV rms (up to 500kHz), 1.5 m (4.92 ft) length
Details
100:1 PROBE 9666
Max. rated voltage to earth is same as for input module, Max. input voltage 5kV peak (up to 1MHz), 1.5 m (4.92 ft) length
Details
DIFFERENTIAL PROBE 9322
DIFFERENTIAL PROBE 9322 For up to 2kV DC or 1kV AC. Use with either AC Adapter 9418-15, input section cable 46cm (1.51ft), Main unit cable 1.3m (4.27ft)
Details
POWER CORD 9328
Connects the DIFFERENTIAL PROBE 9322 and input units, 15cm (0.49ft)
CONNECTION CORD 9217
Insulated BNC connectors on ends, connects to the insulated BNC terminal on the input unit
Current measurement
CLAMP ON PROBE 3273-50
CLAMP ON PROBE 3273-50 Wide (DC to 50 MHz) range, mA level to 30 A peak current
Details
CLAMP ON PROBE 3274
CLAMP ON PROBE 3274 Wide (DC to 10 MHz) range, mA level to 150 A rms current
Details
CLAMP ON PROBE 3275
CLAMP ON PROBE 3275 Wide (DC to 2 MHz) range, mA-level to 500 A rms current
Details
CLAMP ON PROBE 3276
CLAMP ON PROBE 3276 Wide (DC to 100 MHz) range, mA-level to 30 A rms current
Details
Note: The 3273, 3274, 3275can be directly connected to the VOLTAGE/ CURRENT UNIT 8951

*CLAMP ON SENSOR 9272-10
Enables observation of distorted AC current waveforms
Input: 5 to 10 kHz, switch between 20 and 200-A ranges possible, 2 V AC out
CLAMP ON SENSOR 9271 Can only be used in combination with the SENSOR UNIT 9555-10 or F/V UNIT 8940
Details
UNIVERSAL CLAMP ON CT 9278
UNIVERSAL CLAMP ON CT 9278 Enables waveform observation from DC to distorted AC
Input: 100 kHz DC, up to 200 A, 2 V AC out
Details
*UNIVERSAL CLAMP ON CT 9279
UNIVERSAL CLAMP ON CT 9279 Enables waveform observation from DC to distorted AC
Input: 20 kHz DC, up to 500 A, 2 V AC out
Details

CONVERSION CABLE 9318
Used to connect the VOLTAGE/ CURRENT UNIT 8951 to the 9270-9272 and 9277-9279 CLAMPs
Note: Either of these 9270 to 9279 can be directly connected to the VOLTAGE/CURRENT UNIT 8951 with the CONVERSION CABLE 9318
Communications items
RS-232C CARD 9557
PCMCIA-compliant
Details
GP-IB CARD 9558
PCMCIA-compliant, * With a GP-IB cable, cord length: 2 m (6.56 ft)
Details
LAN CABLE 9642
Straight/cross conversion connector provided, cable length: 5 m (16.41 ft)
LAN COMMUNICATOR 9333
LAN COMMUNICATOR 9333 Software required to use a LAN connection with Windows 95/98/Me, or Windows NT 4.0
Details
WAVE PROCESSOR 9335
Bundled application software (data acquisition software, Windows 2000 SP4 or later, Windows XP SP2 or later)
Details
Other options
PC CARD 128M 9726
(PCMCIA adapter and compact flash memory card set, 128 MB)
Details
PC CARD 256M 9727
(PCMCIA adapter and compact flash memory card set, 256 MB)
Details
PC CARD 512M 9728
(PCMCIA adapter and compact flash memory card set, 512 MB)
Details
PC CARD 1G 9729
(PCMCIA adapter and compact flash memory card set, 1 GB)
Details
FUNCTION UP DISK 9549(POWER MONITOR)

Adds functions to the MEMORY HiCORDER 8855
CARRYING CASE 9397-01
With casters for easier transport
OVERVIEW OPTION DOWNLOAD CATALOG EXTRAS