Japanese Chinese Korea
MEMORY HiCORDER 8855 < Recorder < Products
Recorder (For waveform capture of high-speed signals -Digital Oscilloscope Series)

MEMORY HiCORDER 8855

OVERVIEW OPTION DOWNLOAD CATALOG EXTRAS  
Factory-installed option *Must specify when ordering
MEMORY BOARD 9645
MEMORY BOARD 9645 (128 Megaword total) Expands memory to 4 times standard size. Specify upon order, factory installation only.
MEMORY BOARD 9645-01
MEMORY BOARD 9645-01 (512 Megaword total) Expands memory to 16 times standard size. Specify upon order, factory installation only.
HD UNIT 9663
HD UNIT 9663 Specify upon order, factory installation only. (20GB)
Note: The MO and HD units cannot be mounted on the unit at the same time.
MO UNIT 9646

Discontinued
Input modules
Input cables are not supplied. Please purchase the appropriate cable for the intended application.
Install by inserting into the main unit. Can be replaced by user.
ANALOG UNIT 8950
ANALOG UNIT 8950 1ch, Voltage input, DC to 10MHz band width
Details
VOLTAGE/ CURRENT UNIT 8951
VOLTAGE/ CURRENT UNIT 8951 1ch, Voltage input, Current input with clamp-on sensor, DC to 4MHz
Details
DC/RMS UNIT 8952
DC/RMS UNIT 8952 1ch, Voltage, DC to 10MHz, or RMS rectifier DC/15 to 500kHz
Details
HIGH RESOLUTION UNIT 8953-10
HIGH RESOLUTION UNIT 8953-10 1ch, Voltage input, DC to 100kHz band width, built in filter for FFT
Details
VOLTAGE/TEMP UNIT 8954
VOLTAGE/TEMP UNIT 8954 1ch, Voltage/DC to 20kHz, or Temperature input with thermocouple
Details
F/V UNIT 8955
F/V UNIT 8955 1ch, Frequency, Rotation, Pulse integration/duty ratio/width
Details
Logic signal measurement
LOGIC PROBE 9327
LOGIC PROBE 9327 4-channel type, for voltage/contact signal ON/OFF detection (response time 0.1μsec or higher, miniature terminal type)
Details
LOGIC PROBE 9321-01
LOGIC PROBE 9321-01 4 isolated channels, ON/OFF detection of AC/DC voltage (miniature terminal type)
Details
LOGIC PROBE 9320-01
LOGIC PROBE 9320-01 4-channel type, for voltage/contact signal ON/OFF detection (response time 0.5μsec, miniature terminal type)
Details
CONVERSION CABLE 9323
CONVERSION CABLE 9323 Used for connecting the 9320/9321 and 8855 series MEMORY HiCORDERs, because the terminal shapes are different.
* This cable is not required for the smallterminal types 9327, 9320-01, and 9321-01.
Voltage measurement (for use with general input modules)
CONNECTION CORD 9790 (Thin Type)
CONNECTION CORD 9790 (Thin Type) CAT II 300 V, ultraflexible 2.8mm (0.11in) diameter test lead cable, 1.5m (4.92ft) length
Note: Attachment clips sold separately.
ALLIGATOR CLIP 9790-01
ALLIGATOR CLIP 9790-01 Red/black set attaches to the ends of test leads (9790)
GRABBER CLIP 9790-02
GRABBER CLIP 9790-02 Red/black set attaches to the ends of test leads (9790)
CONTACT PIN 9790-03
CONTACT PIN 9790-03 Red/black set attaches to the ends of test leads (9790)
CONNECTION CORD 9198
CONNECTION CORD 9198 For low voltage (up to 300V), 1.7m (5.58ft) length
CONNECTION CORD 9197
CONNECTION CORD 9197 For high voltage (up to 600V), 1.8m (5.91ft) length
10:1 PROBE 9665
10:1 PROBE 9665 Max. rated voltage to earth is same as for input module, max. input voltage 1kV rms (up to 500kHz), 1.5m (4.92ft) length
Details
100:1 PROBE 9666
100:1 PROBE 9666 Max. rated voltage to earth is same as for input module, max. input voltage 5kV peak (up to 1MHz), 1.5m (4.92ft) length
Details
High-Voltage measurement (for use with power supply)
DIFFERENTIAL PROBE 9322
DIFFERENTIAL PROBE 9322 For up to 2 kV DC or 1 kV AC. Use with either AC Adapter 9418-15, or via Power Cord.
Details
AC ADAPTER 9418-15
AC ADAPTER 9418-15 For powering Differential probe 9322, 100 to 240V AC
POWER CORD 9328
POWER CORD 9328 Use to the 9322 from the Input modules
PT 9303
PT 9303 Insulation transformer, 400 V or 200 V AC input, 10 V AC output, for AC power line measurement. Required along with the Conversion Adapter 9199. Not CE marked
Current measurement (To connect the clamp-on sensor via the conversion cable, Band width DC to 100kHz class)
UNIVERSAL CLAMP ON CT 9279
UNIVERSAL CLAMP ON CT 9279 Observe waveforms from DC to distorted AC. DC to 20kHz response, input 500A/output 2V AC, Not CE marked
Details
UNIVERSAL CLAMP ON CT 9278
UNIVERSAL CLAMP ON CT 9278 Observe waveforms from DC to distorted AC. DC to 100kHz response, input 200A/output 2V AC
Details
UNIVERSAL CLAMP ON CT 9277
UNIVERSAL CLAMP ON CT 9277 Observe waveforms from DC to distorted AC. DC to 100kHz response, input 20A/output 2V AC
Details
SENSOR UNIT 9555-10
SENSOR UNIT 9555-10 Power supply unit for the 9272 to the 9279 clamp sensors, except for connecting to the 8951, for signal output, the 9217 is necessary.
Details
CLAMP ON SENSOR 9272-10
CLAMP ON SENSOR 9272-10 Enables observation of AC current waveforms. Input: 1 to 100kHz, selectable 20 and 200A rms ranges, 2V AC output
Details
CONVERSION CABLE 9318
CONVERSION CABLE 9318 to connect the 9272 to 9279 and the 8951
Current measurement (Band width DC to 100 MHz class)
CLAMP ON PROBE 3276
CLAMP ON PROBE 3276 DC to 100MHz wideband response, mA-class current up to 30A rms
Details
CLAMP ON PROBE 3275
CLAMP ON PROBE 3275 DC to 2MHz wideband response, mA-class current up to 500A rms
Details
CLAMP ON PROBE 3274
CLAMP ON PROBE 3274 DC to 10MHz wideband response, mA-class current up to 150A rms
Details
CLAMP ON PROBE 3273-50
CLAMP ON PROBE 3273-50 DC to 50MHz wideband response, mA-class current up to 30A rms
Details
POWER SUPPLY 3272
POWER SUPPLY 3272 Connect and power up to one CLAMP ON PROBE to use in combination with voltage input modules
Details
POWER SUPPLY 3269
POWER SUPPLY 3269 Connect and power up to four CLAMP ON PROBEs to use in combination with voltage input modules
Details
Current measurement * Use for commercial power line, 50/60 Hz (Useless the power supply)
CLAMP ON PROBE 9018-50
CLAMP ON PROBE 9018-50 Enables observation of AC current waveforms. 40Hz to 3kHz response, input 10A to 500A range, output 0.2V AC/range
Details
CLAMP ON PROBE 9132-50
CLAMP ON PROBE 9132-50 Enables observation of AC current waveforms. 40Hz to 1kHz response, input 20A to 1000A range, output 0.2V AC/range
Details
Printer options
RECORDING PAPER 9231
RECORDING PAPER 9231 A4 width 216mm (8.50in) × 30m (98.43ft), 6rolls
PRINTER UNIT 8994
PRINTER UNIT 8994 Factory-installed option. Printing width 200mm (7.87inch).
PC Communication
LAN CABLE 9642
LAN CABLE 9642 Straight Ethernet cable, supplied with straight to cross conversion cable, 5m (16.41ft) length
GP-IB CARD 9558
GP-IB CARD 9558 PCMCIA-compliant, cord length: 2m (6.6ft)
LAN COMMUNICATOR 9333
LAN COMMUNICATOR 9333 Application software to create a LAN connection, Compatible with Windows 95/98/Me, Windows NT 4.0/2000/XP
PC Software
WAVE PROCESSOR 9335
WAVE PROCESSOR 9335 Convert data, print and display waveforms.
Windows 2000/XP/Vista (32-bit), Windows 7 (32-bit/64-bit)
Removable storage (CF card)
* PC Card Precaution
Use only PC Cards sold by HIOKI. Compatibility and performance are not guaranteed for PC cards made by other manufacturers. You may be unable to read from or save data to such cards.
PC CARD 2G 9830
PC CARD 1G 9729 Supplied with PC Card adapter, 2GB capacity
Details
PC CARD 1G 9729
PC CARD 1G 9729 Supplied with PC Card adapter, 1GB capacity
Details
PC CARD 512M 9728
PC CARD 512M 9728 Supplied with PC Card adapter, 512MB capacity
Details
PC CARD 256M 9727
PC CARD 256M 9727 Supplied with PC Card adapter, 256MB capacity
Details
Other options
CONNECTION CORD 9217
CONNECTION CORD 9217 Cord has insulated BNC connectors at both ends, and connects to insulated BNC connectors on input module. 1.7m (5.58ft) length
CONNECTION CORD 9165
CONNECTION CORD 9165 Cord has metallic BNC connectors at both ends, and connects to metallic BNC connectors. 1.5m (4.92ft) length, Not CE marked
CONVERSION ADAPTER 9199
CONVERSION ADAPTER 9199 Banana-to-BNC, use to connect to BNC terminal on Input Module
FUNCTION UP DISK 9549
(POWER MONITOR)
FUNCTION UP DISK 9549 Adds power monitor functions to the MEMORY HiCORDER 8855.
CARRYING CASE 9397-01
CARRYING CASE 9397-01 With casters for easier transport.
OVERVIEW OPTION DOWNLOAD CATALOG EXTRAS