Japanese Chinese Korea
MEMORY HiCORDER 8826 < Recorder < Products
Recorder (For simultaneous recording of multiple signals)

MEMORY HiCORDER 8826

OVERVIEW OPTION DOWNLOAD CATALOG EXTRAS  
Products marked with an * (asterisk) do not have the CE mark
Storage Media
MEMORY BOARD 9599
Expands instrument memory by 4 times its original size (*user installable)
PC CARD 128M 9726
PCMCIA adapter and compact flash memory card set, 128 MB
Details
PC CARD 256M 9727
PCMCIA adapter and compact flash memory card set, 256 MB
Details
PC CARD 512M 9728
PCMCIA adapter and compact flash memory card set, 512 MB
Details
PC CARD 1G 9729
PCMCIA adapter and compact flash memory card set, 1 GB
Details
Input modules
Install or replace simply by inserting the module into the base unit
Note:Input cords are not provided. Please purchase the appropriate input cord for the probe type and application separately.
ANALOG UNIT 8936 ANALOG UNIT 8936

VOLTAGE/TEMP UNIT UNIT 8937 VOLTAGE/TEMP UNIT UNIT 8937

FFT ANALOG UNIT 8938 FFT ANALOG UNIT 8938

STRAIN UNIT 8939 STRAIN UNIT 8939

F/V UNIT 8940
F/V UNIT 8940 * 8826 Ver. 2.10 or later can be used (Current probes with a serial number of No. 1999-0338386 or later can be used, older types cannot be used.)
Details
CHARGE UNIT 8947
CHARGE UNIT 8947 * 8826 Ver. 2.20 or later can be used
Details
Logic Signal Measurement
LOGIC PROBE 9320
LOGIC PROBE 9320-01 4-channels, on/off detection of voltage/contact signal
Details
LOGIC PROBE 9321
LOGIC PROBE 9320-01 4-channel isolated, on/off detection of AC/DC voltage
Details
Voltage measurement
CONNECTION CORD 9197
For up to 500 V, 1.5 m (4.92 ft) length
Details
CONNECTION CORD 9198
For up to 300 V, 1.5 m (4.92 ft) length
Details
DIFFERENTIAL PROBE 9322
DIFFERENTIAL PROBE 9322 For up to 2kV DC or 1kV AC. Use with either AC Adapter 9418-15
Details
POWER CORD 9324
Connects the DIFFERENTIAL PROBE 9322 and logic terminal of the MEMORY HiCORDER
POWER CORD 9325
Connects the DIFFERENTIAL PROBE 9322 and sensor terminal of the F/V UNIT 8940
CONNECTION CORD 9217
Insulation BNC-to-insulation BNC, use to connect to insulation-BNC terminal on Input Module
*CONNECTION CORD 9165
Metal BNC-to-metal BNC, use to connect to metal-BNC terminal on Input Module
*PT 9303
Insulation transformer, 400 V or 200 V AC input, 10 V AC output, for AC power line measurement.
Details
Current measurement
CLAMP ON PROBE 9018-50
CLAMP ON PROBE 9018-50 Input from 10 to 500 A, 40 Hz to 3 kHz for 0.2 V AC output, BNC terminal
Details
*CLAMP ON PROBE 9132-10
CLAMP ON PROBE 9132-10 Input from 20 to 1000 A, 40 Hz to 1 kHz for 0.2 V AC output. BNC terminal
Details
*LINE SPLITTER CT-101A
rated current 500 A AC/DC (continuous 650 A rms/920 A peak) For 100V/15A, convenient for measuring 100 V AC line current with clamp-on probe
Details
SENSOR UNIT 9555-10
SENSOR UNIT 9555 power supply for the 9270 / 9271 / 9272 / 9272-10 / 9277 / 9278 / 9279, single sensor connectable, includes terminal for waveform output
Details
CONVERSION CABLE 9318
Connects CLAMP ON SENSORS 9270/ 9271/ 9272 to F/V UNIT 8940
*CLAMP ON SENSOR 9272-10
Enables observation of distorted AC current waveforms
Input: 5 to 10 kHz, switch between 20 and 200-A ranges possible, 2 V AC out
CLAMP ON SENSOR 9271 Can only be used in combination with the SENSOR UNIT 9555-10 or F/V UNIT 8940
Details

UNIVERSAL CLAMP ON CT 9277
UNIVERSAL CLAMP ON CT 9277 Enables waveform observation from DC to distorted AC
Input: Dc to 100 kHz, up to 20 A, 2 V AC out
Details
UNIVERSAL CLAMP ON CT 9278
UNIVERSAL CLAMP ON CT 9278 Enables waveform observation from DC to distorted AC
Input: DC to 100 kHz, up to 200 A, 2 V AC out
Details
UNIVERSAL CLAMP ON CT 9279
UNIVERSAL CLAMP ON CT 9278 Enables waveform observation from DC to distorted AC
Input: DC to 20 kHz, up to 500 A, 2 V AC out Can only be used in combination with the SENSOR UNIT 9555-10 or F/V UNIT 8940
Details
SENSOR UNIT 9555-10
SENSOR UNIT 9555 power supply for the 9270 / 9271 / 9272 / 9272-10 / 9277 / 9278 / 9279, single sensor connectable, includes terminal for waveform output
Details
CONVERSION CABLE 9318
Connects CLAMP ON SENSORS 9277/ 9278/ 9279 to F/V UNIT 8940

CLAMP ON PROBE 3273-50
CLAMP ON PROBE 3273-50 Wide (DC to 50 MHz) range, mA-level to 30 A peak current. Requires power from 3272 or 3269 or F/V UNIT 8940
Details
CLAMP ON PROBE 3274
CLAMP ON PROBE 3274 Wide (DC to 10 MHz) range, mA-level to 150 A rms current. Requires power from 3272 or 3269
Details
CLAMP ON PROBE 3275
CLAMP ON PROBE 3275 Wide (DC to 2 MHz) range, mA-level to 500 A rms current, Requires power from 3272 or 3269
Details
CLAMP ON PROBE 3276
CLAMP ON PROBE 3276 Wide (DC to 100 MHz) range, mA-level to 30 A rms current, Requires power from 3272 or 3269
Details
POWER SUPPLY 3272
POWER SUPPLY 3272 the 3272 is required for 3273-50, 3274, 3275, 3276
Details
POWER SUPPLY 3269
POWER SUPPLY 3269 the 3269 is required for 3273-50, 3274, 3275, 3276
Details
CONVERSION CABLE 9319
Connects 3273-50 to F/V UNIT 8940
PC communication
RS-232C CARD 9557
PCMCIA-compliant
Details
GP-IB CARD 9558
PCMCIA-compliant, * With a GP-IB cable, cord length: 2 m (6.56 ft)
Details
LAN CARD (HIOKI - tested)
compliant, Manufactured by third parties
Details
LAN CABLE 9642
Straight/cross conversion connector provided, cable length: 5 m (16.41 ft)
LAN COMMUNICATOR 9333
LAN COMMUNICATOR 9333 Software required to use a LAN connection with Windows 95/98/Me, or Windows NT 4.0
Details
WAVE PROCESSOR 9335
Bundled application software (data acquisition software, Windows 2000 SP4 or later, Windows XP SP2 or later)
Details
Printer
RECORDING PAPER 9229
2 64 mm (10.39 i n) × 30 m (98.43ft), 6 rolls set
RECORDING PAPER 9229-01
perforated type, 264 mm (10.39 in) × 30 m (98.43 ft), 6 r olls set
Other options
CONVERSION ADAPTER 9199
Banana-to-BNC, use to connect to BNC terminal on Input Module
OVERVIEW OPTION DOWNLOAD CATALOG EXTRAS