| Recorder (For simultaneous recording of multiple signals) |
MEMORY HiCORDER 8826 |
| Products marked with an * (asterisk) do not have the CE mark |
 |
| MEMORY BOARD 9599 |
 |
 |
Expands instrument memory by 4 times its original size (*user installable) |
|
|
|
| PC CARD 128M 9726 |
 |
 |
PCMCIA adapter and compact flash memory card set, 128 MB |
|
Details |
|
|
|
| PC CARD 256M 9727 |
 |
 |
PCMCIA adapter and compact flash memory card set, 256 MB |
|
Details |
|
|
 |
| PC CARD 512M 9728 |
 |
 |
PCMCIA adapter and compact flash memory card set, 512 MB |
|
Details |
|
|
|
| PC CARD 1G 9729 |
 |
 |
PCMCIA adapter and compact flash memory card set, 1 GB |
|
Details |
|
|
|
 |
 |
 |
 |
 |
Input modules |
 |
Install or replace simply by inserting the module into the base unit Note:Input cords are not provided. Please purchase the appropriate input cord for the probe type and application separately. |
 |
 |
ANALOG UNIT 8936

|
|
|
|
 |
VOLTAGE/TEMP UNIT UNIT 8937

|
|
|
|
 |
FFT ANALOG UNIT 8938

|
|
|
 |
 |
STRAIN UNIT 8939

|
|
|
|
| F/V UNIT 8940 |
 |
 |
* 8826 Ver. 2.10 or later can be used (Current probes with a serial number of No. 1999-0338386 or later can be used, older types cannot be used.) |
|
Details |
|
|
|
| CHARGE UNIT 8947 |
 |
 |
* 8826 Ver. 2.20 or later can be used |
|
Details |
|
|
 |
| LOGIC PROBE 9320 |
 |
 |
4-channels, on/off detection of voltage/contact signal |
|
Details |
|
|
|
| LOGIC PROBE 9321 |
 |
 |
4-channel isolated, on/off detection of AC/DC voltage |
|
Details |
|
|
|
 |
| CONNECTION CORD 9197 |
 |
 |
For up to 500 V, 1.5 m (4.92 ft) length |
|
Details |
|
|
|
| CONNECTION CORD 9198 |
 |
 |
For up to 300 V, 1.5 m (4.92 ft) length |
|
Details |
|
|
|
| DIFFERENTIAL PROBE 9322 |
 |
 |
For up to 2kV DC or 1kV AC. Use with either AC Adapter 9418-15 |
|
Details |
|
|
 |
| POWER CORD 9324 |
 |
 |
Connects the DIFFERENTIAL PROBE 9322 and logic terminal of the MEMORY HiCORDER |
|
|
|
| POWER CORD 9325 |
 |
 |
Connects the DIFFERENTIAL PROBE 9322 and sensor terminal of the F/V UNIT 8940 |
|
|
|
| CONNECTION CORD 9217 |
 |
 |
Insulation BNC-to-insulation BNC, use to connect to insulation-BNC terminal on Input Module |
|
|
 |
| *CONNECTION CORD 9165 |
 |
 |
Metal BNC-to-metal BNC, use to connect to metal-BNC terminal on Input Module |
|
|
|
| *PT 9303 |
 |
 |
Insulation transformer, 400 V or 200 V AC input, 10 V AC output, for AC power line measurement. |
|
Details |
|
|
|
 |
| CLAMP ON PROBE 9018-50 |
 |
 |
Input from 10 to 500 A, 40 Hz to 3 kHz for 0.2 V AC output, BNC terminal |
|
Details |
|
|
|
| *CLAMP ON PROBE 9132-10 |
 |
 |
Input from 20 to 1000 A, 40 Hz to 1 kHz for 0.2 V AC output. BNC terminal |
|
Details |
|
|
|
| *LINE SPLITTER CT-101A |
 |
 |
For 100V/15A, convenient for measuring 100 V AC line current with clamp-on probe |
|
Details |
|
|
 |
| SENSOR UNIT 9555-10 |
 |
 |
power supply for the 9270 / 9271 / 9272 / 9272-10 / 9277 / 9278 / 9279, single sensor connectable, includes terminal for waveform output |
|
Details |
|
|
|
| CONVERSION CABLE 9318 |
 |
 |
Connects CLAMP ON SENSORS 9270/ 9271/ 9272 to F/V UNIT 8940 |
|
|
|
| *CLAMP ON SENSOR 9272-10 |
 |
Enables observation of distorted AC current waveforms Input: 5 to 10 kHz, switch between 20 and 200-A ranges possible, 2 V AC out |
|
 |
Can only be used in combination with the SENSOR UNIT 9555-10 or F/V UNIT 8940 |
|
Details |
|
|
 |
|
 |
| UNIVERSAL CLAMP ON CT 9277 |
 |
 |
Enables waveform observation from DC to distorted AC Input: Dc to 100 kHz, up to 20 A, 2 V AC out |
|
Details |
|
|
|
| UNIVERSAL CLAMP ON CT 9278 |
 |
 |
Enables waveform observation from DC to distorted AC Input: DC to 100 kHz, up to 200 A, 2 V AC out |
|
Details |
|
|
|
| UNIVERSAL CLAMP ON CT 9279 |
 |
 |
Enables waveform observation from DC to distorted AC Input: DC to 20 kHz, up to 500 A, 2 V AC out Can only be used in combination with the SENSOR UNIT 9555-10 or F/V UNIT 8940 |
|
Details |
|
|
 |
| SENSOR UNIT 9555-10 |
 |
 |
power supply for the 9270 / 9271 / 9272 / 9272-10 / 9277 / 9278 / 9279, single sensor connectable, includes terminal for waveform output |
|
Details |
|
|
|
| CONVERSION CABLE 9318 |
 |
 |
Connects CLAMP ON SENSORS 9277/ 9278/ 9279 to F/V UNIT 8940 |
|
|
|
 |
|
 |
| CLAMP ON PROBE 3273-50 |
 |
 |
Wide (DC to 50 MHz) range, mA-level to 30 A peak current. Requires power from 3272 or 3269 or F/V UNIT 8940 |
|
Details |
|
|
|
| CLAMP ON PROBE 3274 |
 |
 |
Wide (DC to 10 MHz) range, mA-level to 150 A rms current. Requires power from 3272 or 3269 |
|
Details |
|
|
|
| CLAMP ON PROBE 3275 |
 |
 |
Wide (DC to 2 MHz) range, mA-level to 500 A rms current, Requires power from 3272 or 3269 |
|
Details |
|
|
 |
| CLAMP ON PROBE 3276 |
 |
 |
Wide (DC to 100 MHz) range, mA-level to 30 A rms current, Requires power from 3272 or 3269 |
|
Details |
|
|
|
| POWER SUPPLY 3272 |
 |
 |
the 3272 is required for 3273-50, 3274, 3275, 3276 |
|
Details |
|
|
|
| POWER SUPPLY 3269 |
 |
 |
the 3269 is required for 3273-50, 3274, 3275, 3276 |
|
Details |
|
|
 |
| CONVERSION CABLE 9319 |
 |
 |
Connects 3273-50 to F/V UNIT 8940 |
|
|
|
 |
| RS-232C CARD 9557 |
 |
 |
PCMCIA-compliant |
|
Details |
|
|
|
| GP-IB CARD 9558 |
 |
 |
PCMCIA-compliant, * With a GP-IB cable, cord length: 2 m (6.56 ft) |
|
Details |
|
|
|
| LAN CARD (HIOKI - tested) |
 |
 |
compliant, Manufactured by third parties |
|
Details |
|
|
 |
| LAN CABLE 9642 |
 |
 |
Straight/cross conversion connector provided, cable length: 5 m (16.41 ft) |
|
|
|
| LAN COMMUNICATOR 9333 |
 |
 |
Software required to use a LAN connection with Windows 95/98/Me, or Windows NT 4.0 |
|
Details |
|
|
|
| WAVE PROCESSOR 9335 |
 |
 |
Bundled application software (data acquisition software, Windows 2000 SP4 or later, Windows XP SP2 or later) |
|
Details |
|
|
 |
| RECORDING PAPER 9229 |
 |
 |
2 64 mm (10.39 i n) × 30 m (98.43ft), 6 rolls set |
|
|
|
| RECORDING PAPER 9229-01 |
 |
 |
perforated type, 264 mm (10.39 in) × 30 m (98.43 ft), 6 r olls set |
|
|
|
 |
| CONVERSION ADAPTER 9199 |
 |
 |
Banana-to-BNC, use to connect to BNC terminal on Input Module |
|
|
|
 |
|