Japanese Chinese Korea
h_clampfield.jpg
DIGITAL HiTESTER 3803 < Multi Meters < Products
For basic applications (Digital Multi Meter)

DIGITAL HiTESTER 3803

CE CAT III 600V
CAT II 1000V
Ull RS-232C
OPTION
OVERVIEW OPTION DOWNLOAD CATALOG  
Compact and basic type DMM
  • Built-in with a 600V, 10kA interrupting capacity fuse
  • Basic accuracy ±0.6%
Regarding DMM Accuracy
Due to the many ranges and functions available in a DMM, only the basic accuracy is indicated for reference. Please refer to the individual catalogs for detailed accuracy information.
Basic specifications (Accuracy guaranteed for 1 year)
DC Voltage 399.9mV to 1000V, 5ranges (Basic accuracy: ±0.6% rdg. ±2 dgt.)
AC Voltage 40 to 500Hz 399.9mV to 1000V, 5ranges (Basic accuracy: ±2% rdg. ±2dgt. /Average rectified)
Resistance 399.9Ω to 39.99MΩ, 6ranges (Basic accuracy: ±0.6% rdg. ±3 dgt.)
DC Current 399.9μA to 10.00A, 5ranges (Basic accuracy: ±1.5% rdg. ±2 dgt.)
AC Current 40 to 500Hz 399.9μA to 10.00A, 5ranges (Basic accuracy: ±2% rdg. ±2dgt. /Average rectified)
Continuity Buzzer sounds at a resistance 34.5Ω or less
Diode check Testing voltage: 3V or less, Testing current: 1.65mA
Other functions Data hold, Auto-power save, RS-232C / USB communication
Display Digital LCD, max. 3999 dgt.
Sampling rate 1.3 times/sec
Power consumption 6F22 manganese battery × 1, Continuous use: 200 hours
Dimensions, mass 83mm (3.27in) W × 178mm (7.01in) H × 58mm (2.28in) D, 400g (14.1oz) (with holster and battery)
Supplied accessories TEST LEAD 3851-10×1, Holster×1, 6F22 manganese battery×1 (for trial purposes only)