| Model 3454-11/51 |
250 V DC (testing voltage), 4.000 MΩ to 500 MΩ (measurement range), Accuracy at first effective range ±3 %rdg. ±4 dgt. at 0.200 to 50.0 MΩ
500 V DC (testing voltage), 4.000 MΩ to 500 MΩ (measurement range), Accuracy at first effective range ±3 %rdg. ±4 dgt. at 0.200 to 50.0 MΩ
1000 V DC (testing voltage), 4.000 MΩ to 4000 MΩ (measurement range), Accuracy at first effective range ±3 %rdg. ±4 dgt. at 0.200 to 200.0 MΩ |
| Model 3454-10 |
50 V DC (testing voltage), 4.000 MΩ to 200.0 MΩ (measurement range), Accuracy at first effective range ±3 %rdg. ±4 dgt. at 0.200 to 10.00 MΩ
125 V DC (testing voltage), 4.000 MΩ to 200.0 MΩ (measurement range), Accuracy at first effective range ±3 %rdg. ±4 dgt. at 0.200 to 10.00 MΩ
250 V DC (testing voltage), 4.000 MΩ to 2000 MΩ (measurement range), Accuracy at first effective range ±3 %rdg. ±4 dgt. at 0.200 to 100.0 MΩ
500 V DC (testing voltage), 4.000 MΩ to 2000 MΩ (measurement range), Accuracy at first effective range ±3 %rdg. ±4 dgt. at 0.200 to 100.0 MΩ |
| Low resistance (continuity) |
40.00 ohm to 4.000 MΩ, Short circuit current:200 mA, Open terminal voltage:4 to 6 V |
| AC voltage range |
0 to 750 V (50 / 60 Hz) ± 3 % rdg. ± 6 dgt., Input impedance : 100 k-ohm |
| Power supply |
R6P(AA) manganese batteries × 4 or LR6(AA)alkaline batteries × 4 |
| Dimensions, mass |
175 mm(6.9 in)W × 148 mm(5.9 in)H × 56 mm(2.3 in)D, 530 g (18.7 oz) |
| Accessories |
TEST PROB 9294 (for 3454-11/ 3454-10), TEST PROBE 9289 (for 3454-51), Strap band (1) |
|