| Clamp Meters (Current Meters -for AC only, basic type-) |
CLAMP ON HiTESTER 3280-10, 3280-20 |
|
 |
|
 CAT III 600 V (Current) CAT III 300 V (Voltage) CAT II 600 V (Voltage) |
 Max. rated voltage to earth 600V rms insulated wire |
 |
|
 |
 |
|
|
 |
 |
| Easy clamping in narrow locations with 16 mm slim body |
 |
- Model 3280-10: Display about nearest basic wave element of harmonic wave by average rectified
- Model 3288-20: True RMS value display of harmonic wave by true RMS rectified
- Wide range of Max. 1000 A, Drop proof design withstands dropping from a height of 1 meter
|
 |
| Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times) |
 |
| |
3280-10 |
3280-20 |
| AC Current |
41.99 to 1000 A, 3 ranges (50 to 60 Hz, Average rectified), Basic accuracy: ±1.5 % rdg. ±5 dgt. |
41.99 to 1000 A, 3 ranges (40 Hz to 1 kHz, True RMS), Basic accuracy: ±1.5 % rdg. ±5 dgt. |
| DC Voltage |
419.9 mV to 600 V, 5 ranges, Basic accuracy: ±1.3 % rdg. ±4 dgt. |
| AC Voltage |
4.199 V to 600 V, 4 ranges (50 to 500 Hz, Average rectified) Basic accuracy: ±2.3 % rdg. ±8 dgt. |
4.199 V to 600 V, 4 ranges (50 to 500 Hz, True RMS) Basic accuracy: ±2.3 % rdg. ±8 dgt. |
| Crest factor |
None |
2.5 and under (1.5 at f.s. of range) |
| Resistance |
419.9 Ω to 41.99 MΩ, 6 ranges, Basic accuracy: ±2 % rdg. ±4 dgt. |
| Other function |
Continuity: (50 Ω ±40 Ω) or less buzzer sounds, Data hold, Auto power save, Drop proof design withstands dropping onto a concrete floor from a height of 1 meter |
| Display |
LCD, max. 4199 dgt., Display refresh rate: 2.5 times/s, 1 time/3 seconds |
| Power supply |
Coin type lithium battery (CR2032) ×1, Continuous use 150 hours |
Coin type lithium battery (CR2032) ×1, Continuous use 50 hours |
| Core jaw dia. |
φ 33 mm (1.30 in) |
| Dimensions, mass |
57 mm (2.24 in) W × 175 mm (6.89 in) H × 16 mm (0.63 in) D, 100 g (3.5 oz) |
| Supplied accessories |
TEST LEAD L9208 ×1, CARRYING CASE 9398 ×1, Instruction Manual ×1 |
|
|