Basic specifications
Measurement Function Phase detection (positive,negative),live wire check (R-S/S-T only)
Voltage Detection Method Electrostatic induction method
Voltage Range 70 to 600V AC (50/60Hz)(sine wave,continuous input)
Clamp Diameter 17mm(0.67 in) max.of insulated wiring
Display
Phase Detection : Positive ; 4 LEDs lit in clockwise order and 3 short beeps
  Negative ; 4 LEDs lit in counterclockwise order and one continuous beep
Live Wire Check : R-S and S-T lamps will light if voltage between wires are within voltage range
Battery Check Function ON lamp blinks to indicate battery low status when instrument is turned on
Auto Power Off Auto shut off if no activity is detected after power is turned ON for 15 minutes
Power supply Two AA size batteries × 2 (rated voltage:DC3.0V; maximum rated ower:300mVA)
Continuous Use approx.70 hours (standby)
Dimensions, mass 70 mm (2.76 in)W × 75 mm (2.95 in)H × 30 mm (1.18 in)D, 200 g (7.1 oz),
Cord length : 0.7m(27.56 in)
Accessories Carrying case(1), strap(1), R6P manganese batteries(2), spiral tube(1)